4. Adjustment of the distance between spindle and pivot point
We recommend to use the Clearaudio
alignment gauge (Art. No. AC005/IEC, also available from
www.analogshop.de) for the exact setting of the tonearm pivot point.
Make sure that the distance between spindle and the pivot point of the tonearm is exactly 222mm.
You can adjust the distance by rotating the tonearm base.
Please tighten the tonearm base and check the measurement again after adjustment.
Pic. 7: Distance from pivot to stylus
222 mm
5. Adjustment of the tonearm
The following settings require to mount the cartridge on the headshell.
Always follow the cartridge manufacturer’s instructions.
Leave the stylus protector on your cartridge to avoid
any damages!
Now you can connect the respective signal cable with the
matching color pins of the cartridge.
Please note the following colour coding:
Red:
right channel / R+
Green:
right channel / R
White:
left channel / L+
Blue:
left channel / L
Connect the pins of your cartridge to the jacks of the headshell or tonearm cable, taking care not
to use too much force.
Use suitable precision pliers or tweezers for assistance if necessary.
Pic. 8: Mounting the cartridge