![Cleantecs LR-180-GTR Operating Instructions Manual Download Page 29](http://html1.mh-extra.com/html/cleantecs/lr-180-gtr/lr-180-gtr_operating-instructions-manual_2620545029.webp)
29
BA 0304972 R00 2021-08
Commissioning
Connecting the high-pressure cleaner
Switch to stop
Check the high-pressure filter in
the connection nipple
�
Take a socket spanner
[9]
and po-
sition it onto the connection socket
nipple
[10]
until it stands up on the
high-pressure filter
[11]
.
�
Turn the socket spanner until it
engages. Screw in a counter-clockwise
direction until the high-pressure filter
[12]
can be loosened.
�
Check the high-pressure filter and the
connection nipple for dirt.
�
Clean or replace the high-pressure
filter if necessary.
�
Clean the connection nipple of impuri-
ties with low-pressure water. Be careful
not to flush dirt particles into the
LR-180-GTR.
�
Screw the high-pressure filter back in
clockwise, hand-tight.
Preparing the high-pressure
cleaner
Connect the high-pressure cleaner
according to the operating instructions
of the unit.
Connect the LR-180-GTR to the
high-pressure
cleaner
Connecting the sunblind cleaner to the
high-pressure cleaner:
�
Rinse the high-pressure hose by
starting the high-pressure cleaner and
stopping it again after 30 seconds.
�
Check whether the start-stop switch
[13]
is set to stop.
[9]
[10]
[12]
[Stop position]
[11]
[13]
Check the high-pressure filter