- CLEANING THE ROBO 40 -
The Robo 40 requires regular cleaning and care. To achieve flawless cleaning results, dirtying such as can
be seen in the illustrations A/B/C must not occur.
Point 1
First of all, remove the suction bar (see "Suction Nozzle" chapter). Then remove the fresh water tank.
Position the Robo 40 on the transport cart (D) and tip it.
Point 2
It is now easy to access the areas that have to be cleaned. By unscrewing the 4 Allen screws, (E) the roller
brushes (1) can be disassembled. Point 2 is not necessary if there is only slight dirtying.
Point 3
Clean the roller brushes,(1) brush strip and housing with water and a cleaning agent.
Point 4
Caution: During each cleaning, check the condition of the water lines to make sure they are secure and
clean.
Point 5
Position the roller brushes (1) and screw them together again with the Allen screws. Clean the suction bar
and install it as described in the chapter entitled "Replacing the suction lips". At the end, use a damp cloth to
clean the sensor shield and the panel of the Robo 40.
Note:
Perform all work with the proper care. Maintenance work as well as repair work of any type may only be
performed by the manufacturer of the unit or by professionals while observing all relevant safety regulations.
A
B
C
D
1