background image

 

Pro

OX

 

7000

SXT

 

Installation

 

&

 

Startup

 

Guide

 

Page

 

11

            

www.cleanwaterstore.com

 

    

Rev

 

030514

 

Troubleshooting

 

the

 

Pro

OX

 

7000

 

Iron

 

Filter

 

System

 

One

 

problem

 

that

 

may

 

occur

 

is

 

if

 

you

 

do

 

not

 

have

 

enough

 

backwash

 

flow

 

rate

 

to

 

properly

 

clean

 

the

 

Pro

OX

 

filter.

  

You

 

can

 

verify

 

the

 

backwash

 

flow

 

rate

 

by

 

running

 

the

 

drain

 

line

 

into

 

a

 

bucket

 

and

 

timing

 

it

 

when

 

the

 

Fleck

 

7000

 

is

 

in

 

Cycle

 

1

 

or

 

backwash.

    

In

 

some

 

cases,

 

the

 

Fleck

 

7000

 

may

 

not

 

be

 

programmed

 

correctly.

  

See

 

the

 

Fleck

 

7000

 

service

 

manual

 

for

 

instructions

 

on

 

how

 

to

 

access

 

the

 

master

 

programming.

  

Your

 

Fleck

 

7000

 

should

 

be

 

set

 

for

 

FLtr

 

or

 

Filter

 

mode

 

and

 

have

 

two

 

cycles,

 

backwash

 

and

 

rinse.

 

If

 

you

 

are

 

still

 

getting

 

some

 

iron

 

through

 

the

 

system,

 

you

 

can

 

adjust

 

the

 

filter

 

to

 

backwash

 

every

 

1

 

or

 

2

 

days.

   

In

 

some

 

cases

 

if

 

the

 

untreated

 

water

 

is

 

high

 

in

 

hydrogen

 

sulfide,

 

or

 

the

 

iron

 

level

 

is

 

over

 

5

 

ppm,

 

a

 

chlorinator

 

system

 

may

 

be

 

needed

 

before

 

the

 

iron

 

filter,

 

in

 

order

 

for

 

the

 

Pro

OX

 

media

 

to

 

work

 

properly.

    

  

What

 

to

 

Do

 

If

 

Your

 

Filter

 

Tank

 

Does

 

Not

 

Sit

 

Level

 

on

 

the

 

Floor

 

Your

 

black

 

filter

 

tank

 

base

 

is

 

not

 

glued

 

to

 

the

 

bottom

 

of

 

your

 

tank.

  

Occasionally

 

tank

 

bases

 

will

 

become

 

crooked

 

during

 

shipment.

  

If

 

you

 

find

 

that

 

that

 

your

 

tank

 

does

 

not

 

sit

 

level

 

on

 

the

 

floor,

 

you

 

can

 

easily

 

adjust

 

it

 

by

 

holding

 

the

 

empty

 

tank

 

and

 

rapping

 

it

 

on

 

a

 

concrete

 

or

 

solid

 

floor

 

once

 

or

 

twice

 

in

 

order

 

to

 

level

 

it.

  

 

Pro

OX

 

7000

 

Filter

 

System

 

(Non

 

Flow

 

Sensor)

 

Standard

 

Programming

 

Guide

 

This

 

is

 

for

 

the

 

standard

 

Pro

OX

 

filter

 

systems

 

that

 

do

 

NOT

 

have

 

the

 

optional

 

flow

 

sensor.

  

If

 

your

 

system

 

is

 

equipped

 

with

 

a

 

flow

 

sensor,

 

see

 

next

 

section

 

Page

 

13.

   

There

 

are

 

two

 

types

 

of

 

programming,

 

standard

 

USER

 

PROGRAMMING,

 

where

 

you

 

can

 

set

 

the

 

time

 

of

 

day

 

and

 

days

 

between

 

backwashes.

  

The

 

second

 

type

 

is

 

MASTER

 

PROGRAMMING

 

where

 

you

 

can

 

set

 

the

 

length

 

of

 

the

 

backwash

 

and

 

rinse

 

cycles,

 

and

 

make

 

sure

 

the

 

control

 

is

 

set

 

to

 

the

 

correct

 

settings

 

for

 

your

 

type

 

of

 

Pro

OX

 

filter:

 

User

 

Programming

   

1.

 

Press

 

the

 

Up

 

and

 

Down

 

buttons

 

for

 

five

 

seconds

 

while

 

in

 

service,

 

and

 

the

 

time

 

of

 

day

 

is

 

NOT

 

set

 

to

 

12:01

 

PM.

 

2.

 

Day

 

Override

 

(Display

 

Code

 

DO):

 

Set

 

to

 

1

 

to

 

14

 

based

 

on

 

your

 

particular

 

filter

 

system

 

requirements.

  

Use

 

the

 

Up

 

or

 

Down

 

arrows

 

to

 

change

 

the

 

setting.

 

This

 

is

 

the

 

critical

 

setting

 

that

 

allows

 

your

 

filter

 

to

 

backwash

 

Summary of Contents for PRO-OX 7000-SXT

Page 1: ...g iron free water for many years Please review this start up guide entirely before beginning to install your system and follow the steps outlined for best results PRO OX MEDIA CONTAINS DUST USE PAPER MASK AND VENTILATE AREA TO AVOID BREATHING DUST DURING INSTALLATION Questions Call us toll free 1 888 600 5426 or 1 831 462 8500 Email us support cleanwaterstore com See more information on our websit...

Page 2: ... Media Funnel Use 6 Fig 4 Fleck 7000 Bypass and Pipe Connectors 7 Fig 5 Fleck 7000 Bypass Knobs 7 Fig 6 Stainless Steel Backwash Drain Flow Control 8 Maintaining Your Pro OX Filter System 10 Troubleshooting the Pro OX 7000 Iron Filter System 11 What to Do If Your Filter Tank Does Not Sit Level on the Floor 11 Pro OX 7000 Filter System Non Flow Sensor Standard Programming Guide 11 User Programming ...

Page 3: ...led 1 Media funnel In addition each system comes with the following depending on the model ordered 1 0 Cubic Foot Pro OX Quantity Description 1 12 lbs Gravel 2 cubic foot boxes of Pro OX filter media 1 5 Cubic Foot Pro OX Quantity Description 1 16 lbs Gravel 3 cubic foot boxes of Pro OX filter media 2 0 Cubic Foot Pro OX Quantity Description 1 16 lbs Gravel 4 cubic foot boxes of Pro OX filter medi...

Page 4: ... you are also installing a water softener install the softener after the Pro OX filter 2 Make sure to follow to connect the in pipe to the Fleck 7000 SXT inlet and the outlet to the outlet see Fig 2 As you face the Fleck 7000 SXT control from the front the water enters on the right and exits on the left From the back see Fig 2 the water enters on the left The inlet and outlet are attached to the b...

Page 5: ...th the drain tubing How Your Pro OX Filter System Works See Fig 1 In your Pro OX filter the water enters the top of the tank red arrows and flows down through the media and up the distributor tube blue arrows Iron and manganese in the water turns to an oxidized particle upon contact with the media and is trapped in the media During backwash the water flow is reversed and water flows down the distr...

Page 6: ...g 2 Typical Pro OX piping installation with ball valve and hose bib after the filter Filter strainer is optional and useful if there is sand or grit in the water The 25 1 micron filter after is optional and used when there is very fine sediment or colloidal particles over 1 micron present ...

Page 7: ...e and fill tank completely with water This will allow the Pro OX media to become activated and also sanitize the media It will also eliminate the need of purging the air out of the tank later 6 NOTE Regarding Teflon tape and pipe sealants It is OK to use Teflon tape and pipe sealant on the water pipe connector threads where you attach your pipes or plumbing to the Fleck 7000 DO NOT USE any Teflon ...

Page 8: ...n the BY PASS position for now Fig 4 Fleck 7000 Bypass 1 Pipe Connectors 2 9 Lubricate the by pass valve o rings only on the pipe connectors with some vegetable oil or silicone grease and connect the bypass assembly to the Fleck 7000 control by sliding the bypass valve firmly into the body of the Fleck 7000 Once bypass is in far enough you will be able to easily insert the red connector clips DO N...

Page 9: ...or 1 Note that it is desirable to be able to run the drain line into a bucket in order to test the backwash flow rate in the future This is why hard piping the drain line is discouraged however if you do use hard PVC piping for the drain line and you are able to remove the hard PVC drain piping and attach flexible tubing should you ever desire for testing purposes it is OK to use rigid PVC pipe fo...

Page 10: ... important step clears out any foreign material that may be in pipes from the installation If you do not have a valve and hose bib installed after the Pro OX filter you will need to turn the water on inside the house to let the water run Use a bathtub or laundry sink or other fixture that does not have an aerator screen 20 Press the Extra Cycle button for a second or two which will start a manual ...

Page 11: ...he backwash the Fleck 7000 will automatically advance to the rinse cycle 25 After the Pro OX filter has gone through the backwash and rinse press the Extra Cycle button and repeat the backwash and rinse This is the same procedure that needs to be done each time you add Pro OX media in the future that is the Pro OX media must be thoroughly backwashed and rinsed 26 Refer to your Fleck 7000 service m...

Page 12: ...loor Your black filter tank base is not glued to the bottom of your tank Occasionally tank bases will become crooked during shipment If you find that that your tank does not sit level on the floor you can easily adjust it by holding the empty tank and rapping it on a concrete or solid floor once or twice in order to level it Pro OX 7000 Filter System Non Flow Sensor Standard Programming Guide This...

Page 13: ...n the Master Programming Mode is entered all available option setting displays may be viewed and set as needed Depending on current option settings some parameters cannot be viewed or set 1 Display Format Display Code DF Set display to GAL stands for U S Gallons or change to Liters or Cubic Meters if out of the U S Press the Extra Cycle button to go to the next step 2 Valve Type Display code VT Se...

Page 14: ...rogramming and make adjustments if you want to the flow meter setting or Day Override setting Use the User Programming to avoid having to go through the Master Programming for quick changes to these settings below 1 Press the Up and Down buttons for five seconds while in service and the time of day is NOT set to 12 01 PM 2 Day Override Display Code DO Set to 1 to 14 based on your particular filter...

Page 15: ... 3 Control Type Display Code CT Set to Fd This is the Meter Delayed option This tells the Fleck 7000 control to meter or keep track of the amount of water used but then wait until the pre set regeneration backwash and rinse cycles time typically in the middle of the night Press the Extra Cycle button 4 Unit Capacity Display Code C Set to 30 Use this display to set the Unit Capacity This setting sp...

Page 16: ...lay to set the various minutes of each cycle Some of the cycles will be set to 0 Do not set any of the cycles to Off Use the Up or Down arrows to change the setting to the desired setting Press the Extra Cycle button to accept the setting and move to the next parameter a B1 Backwash Set to 8 to 10 minutes b BD Brine Draw Set to 0 c B2 2nd Backwash Set to 0 for most applications d RR Rapid Rinse Se...

Reviews: