Pro
‐
OX
7000
‐
SXT
Installation
&
Startup
Guide
Page
12
www.cleanwaterstore.com
Rev
030514
every
fixed
number
of
days.
See
your
Installation
and
Start
‐
up
Guide
for
more
information
or
contact
us
for
suggestions
for
this
setting.
Press
the
Extra
Cycle
button.
3.
Regeneration
Time
(Display
Code
RT):
Set
to
2:00
am
generally
or
sometime
when
no
water
is
being
used,
and
no
other
filter
or
softener
is
likely
to
be
in
a
regeneration
cycle.
Press
the
Extra
Cycle
button.
4.
Press
the
Extra
Cycle
button
to
end
User
Programming
Mode.
The
timer
will
exit
Diagnostic
Mode
after
60
seconds
if
no
buttons
are
pressed.
Press
the
Extra
Cycle
button
to
exit
Diagnostic
Mode
at
any
time.
Master
Programming
Perform
a
Master
Reset:
Unplug
the
Fleck
7000
from
the
electrical
wall
outlet.
Hold
the
Extra
Cycle
button
while
plugging
in
and
powering
up
the
unit.
This
resets
all
of
the
parameters
in
the
unit.
Enter
Master
Programming
Mode:
Set
the
Time
of
Day
display
to
12:01
P.M.
Press
the
Extra
Cycle
button
(to
exit
Setting
Time
of
Day
mode).
Then
press
and
hold
the
Up
and
Down
buttons
together
until
the
programming
icon
replaces
the
service
icon
and
the
Display
Format
screen
appears.
Note,
that
when
the
Master
Programming
Mode
is
entered,
all
available
option
setting
displays
may
be
viewed
and
set
as
needed.
Depending
on
current
option
settings,
some
parameters
cannot
be
viewed
or
set.
1.
Display
Format
(Display
Code
DF):
Set
display
to
GAL
(stands
for
U.S.
Gallons),
or
change
to
Liters
or
Cubic
Meters
if
out
of
the
U.S.
Press
the
Extra
Cycle
button
to
go
to
the
next
step.
2.
Valve
Type
(Display
code
VT):
Set
to
Fltr.
This
refers
to
‘Filter”,
which
is
correct.
Press
the
Extra
Cycle
button
to
go
to
the
next
step.
3.
Control
Type
(Display
Code
CT):
Set
to
TC.
Refers
to
Time
Clock
type,
which
it
is.
Press
the
Extra
Cycle
button.
4.
Day
Override
(Display
Code
DO):
Set
to
7
or
other
based
on
your
particular
filter
system
requirements.
Use
the
Up
or
Down
arrows
to
change
the
setting.
This
is
the
critical
setting
that
allows
your
filter
to
backwash
every
fixed
number
of
days.
See
your
Installation
and
Start
‐
up
Guide
for
more
information
or
contact
us
for
suggestions
for
this
setting.
Press
the
Extra
Cycle
button.
5.
Regeneration
Time:
(Display
Code
RT):
Set
to
2:00
am
generally
or
sometime
when
no
water
is
being
used,
and
no
other
filter
or
softener
is
likely
to
be
in
a
regeneration
cycle.
Press
the
Extra
Cycle
button.
6.
Regeneration
Cycle
Step
Times:
Use
this
display
to
set
the
various
minutes
of
each
cycle.
Press
the
Extra
Cycle
button
to
accept
the
setting
and
move
to
the
next
parameter.