OPERATION 

SAFETY PRECAUTIONS 

This machine is intended for commercial use. It is 
designed to wet clean carpet and upholstery in a 
indoor environment and is not constructed for any 
other use. Use only recommended cleaning solutions 
and accessory tools. 

All operators must read, understand and practice the 
following safety precautions. 

The following safety-alert symbols are used throughout 
this manual as indicated in their description: 

  WARNING: To warn of hazards or unsafe 

practices which could result in severe personal 
injury or death. 

FOR SAFETY: To identify actions which must be 
followed for safe operation of equipment. 

The following information signals potentially dangerous 
conditions to the operator or equipment. 

FOR SAFETY: 

1.  Do not operate machine: 
 

– 

Unless trained and authorized. 

 

– 

Unless operator manual is read and 
understood. 

 

– 

In flammable or explosive areas.  

 

– 

With damaged cord or plug. 

– 

If not in proper operating condition. 

– 

Unless cord is properly grounded. 

 

– 

In outdoor areas.  

 

– 

In standing water. 

 

– 

With the use of an extension cord. 

2.  Before operating machine: 

 

– 

Make sure all safety devices are in place 
and operate properly. 

3.  When using machine: 
 

– 

Do not run machine over cord. 

 

– 

Do not pull machine by plug or cord. 

 

– 

Do not pull cord around sharp edges or 
corners.  

 

– 

Do not unplug by pulling on cord. 

 

– 

Do not stretch cord. 

 

– 

Do not handle plugs with wet hands.  

 

– 

Keep cord away from heated surfaces.  

– 

Report machine damage or faulty operation 
immediately.  

– 

Follow mixing and handling instructions on 
chemical containers.  

– 

Connect hoses before turning on pump. 

– 

Be sure chemicals are safe and non-toxic. 

4.  Before leaving or servicing machine: 

– 

Turn off machine. 

– 

Unplug cord from wall outlet. 

5.  When servicing machine: 

– 

Unplug cord from wall outlet. 

– 

Avoid moving parts. Do not wear loose 
jackets, shirts, or sleeves.  

– 

Use manufacturer supplied or approved 
replacement parts.  

   WARNING: Hazardous Voltage. Shock or 

electrocution can result. Always unplug machine 
before servicing. 

   WARNING: Flammable materials can cause 

an explosion or fire. Do not use flammable 
materials in tank(s). 

   WARNING: Flammable materials or reactive 

metals can cause an explosion or fire. Do not pick 
up. 

   WARNING: Hot solutions up to 88° C (190°F). 

Do not touch with any part of the body. Use 
thermometer to gauge temperature. 

   WARNING: Contents of solution hoses may 

be under pressure even after pump is off. 

 

GROUNDING INSTRUCTIONS 

Machine must be grounded. If it should 
malfunction or breakdown, grounding provides a 
path of least resistance for electrical current to 
reduce the risk of electrical shock. This machine is 
equipped with a cord having an equipment-
grounding connector and grounding plug. The 
plug must be plugged into an appropriate outlet 
that is properly installed in accordance with all 
local codes and ordinances. Do not remove 
ground pin; if missing, replace plug before use. 
International models will have different cord ends.

 

GROUNDED OUTLET 
            (3 HOLE) 

GROUNDING 
        PIN 

Summary of Contents for Raptor 230H

Page 1: ... 230H Carpet And Upholstery Cleaner Model No 100 652 230 11 gal Extractor CLEANMASTER 11015 47TH AVENUE WEST MUKILTEO WA 98275 U S A FAX 1 800 426 4225 WEBSITE www cleanmaster com CUSTOMER SERVICE 1 425 775 7276 Operator and Parts Manual ...

Page 2: ... supplies may be ordered by phone or mail from any authorized parts and service center distributor or directly from Cleanmaster This machine will provide excellent service However the best results will be obtained at minimum costs if The machine is operated with reasonable care The machine is maintained regularly per the maintenance instructions provided The machine is maintained with manufacturer...

Page 3: ... wet hands Keep cord away from heated surfaces Report machine damage or faulty operation immediately Follow mixing and handling instructions on chemical containers Connect hoses before turning on pump Be sure chemicals are safe and non toxic 4 Before leaving or servicing machine Turn off machine Unplug cord from wall outlet 5 When servicing machine Unplug cord from wall outlet Avoid moving parts D...

Page 4: ...arton for signs of damage Report damages at once to carrier The machine is shipped fully assembled and is ready for use 2 Connect hoses and tool to be used Figure1 3 Using a clean bucket or hose fill solution tank with 41 liters 11 gallons of hot water 60 C 140 F maximum Figure 2 WARNING Flammable materials can cause an explosion or fire Do not use flammable materials in tank s 4 Add a recommended...

Page 5: ...eater Figure 4 This will preheat the entire contents of the solution tank CLEANING CARPETS 1 Activate vacuum pump and heater switches and turn preheat valve to clean position Figure 5 2 Take carpet cleaning wand in hand and squeeze valve trigger while moving the tool in short forward and backward strokes Figure 6 WHILE OPERATING 1 Overlap each path by 50 mm 2 in Warning Flammable materials or reac...

Page 6: ...lean water at the end of the day DRAINING SOLUTION TANK 1 Remove empty out nozzle from its storage bracket Figure 10 and attach to end of solution hose 2 Place empty out nozzle over a bucket and turn on pump until all the solution has been pumped from solution tank 3 Replace empty out nozzle to its storage location FREEZE PROTECTION 1 After draining solution tank as described in steps one and two ...

Page 7: ...ical containers 3 Inspect cord and cord grip for damage Replace immediately if damaged 4 Lubricate metal shaft on recovery tank drain with water resistant oil 5 Lubricate female hose couplers with lightweight oil MONTHLY MAINTENANCE Every 80 Hours of Operation 1 Lubricate wheels with water resistant oil 2 Inspect machine for water leaks and loose hardware QUARTERLY MAINTENANCE Every 250 hours of O...

Page 8: ...d Connect quick couplers Loose or broken wiring Contact Service Center Faulty vacuum switch Contact Service Center Defective vacuum motor Contact Service Center Vacuum motor does not operate Worn carbon brushes Contact Service Center Recovery tank drain valve open Close valve Defective recovery tank lid gasket Replace gasket Clogged float shut off screen Remove recovery tank lid and clean screen L...

Page 9: ...al SOLUTION PUMP 240 V 20 68 bar 300psi 1 0 A VACUUM MOTORS 2 3 STAGE PARALLEL 2 x 240 V 4 6 A 1104 W INLINE HEATER 2 x 240 V 4 1 A 1000 W SEALED WATER LIFT 3454 mm 136 in 200CFM calc TOTAL POWER CONSUMPTION CIRCUIT ONE 240V 9 1A 2184W TOTAL POWER CONSUMPTION CIRCUIT TWO 240V 8 2A 1968W POWER CORDS 2 7 6m 25 ft 3 12 DECIBEL RATING 3 METERS 10 FT FROM MACHINE ON CARPET 77 db A 711 mm 28 in 1016 mm ...

Page 10: ...36456 E3H Raptor CE 04 01 10 ELECTRICAL DIAGRAM RAPTOR 230H 120 V WIRING DIAGRAM ...

Page 11: ...36456 E3H Raptor CE 04 01 11 PARTS LIST RAPTOR 230H TANK GROUP ...

Page 12: ... BR ST TH 1 PART DESCRIPTION QTY G 03 19 O RING VITON 2 020 BLKHD 1 J 48CLNMSTR LID SOLUTION GRNGRANITE CM 1 J 49GRNGRNT LID MEGA E3 ROTO GREEN GRANITE 1 J 57 5 SPACER ROTO 3 OD X 2 4 ID 1 K 05 8 THERMAL CRCT BRKR 2 K 16 85 RELIEF BELL MOUTH CORD 2 K 16 85A NUT NYLON BELL MOUTH 2 K 21WGRY SWITCH SPST WTR RESIS GRY 5 K 28 05 TIE WIRE NYLON 10 SCREW 1 K 28 1 TIE WRAP 8 LONG NATURAL 2 M 0791 03 BRACK...

Page 13: ...36456 E3H Raptor CE 04 01 13 PARTS LIST RAPTOR 230H BASE GROUP ...

Page 14: ...TY G 25 1A KNOB 2 3 WAY VALVE G 25 1 5 1 G 37 VALVE VAC SHUT OFF DUAL 1 J 45BLK PMP MNT DRLD 2 VAC SILNCE BLCK ROTO 1 K 08W CONN AMP 4 CIR MALE W RES 1 K 17 4 CLAMP NYLON CABLE 1 4 2 K 17 5 CLAMPS NYLON CABLE 3 8 2 K 23 23 THERMOSTAT 190 SPST W LDS 2 M 0255 GUARD SPL SCRN CMP EDG CE 2 M 0563 8 BRACKET MTR STARTER CAP 1 M 0790 5 AXIL ROD 1 2 ECONO 1 M 0791 AXIL ROD 1 2 1 M 0791 01 BRACKET PRES RELF...

Page 15: ...MP 300PSI 1 4HP AC CMP 220V110CAM 60HZ XXX 1 2 SL 28 300A MOTOR 300PSI AC CMP 110V 110CAM 60HZ XXX 1 2 SL 28 410MTR MOTOR 300PSI AC CMP 100V 116CAM 50 60HZ XXX 1 2 SL 28 425MTR MOTOR 300PSI AC CMP 220V 110CAM 60HZ XXX 1 2 SL 28 450MTRCE MOTOR 300PSI AC CMP 220V 125CAM 50HZ XXX 3 SL 28 KIT A PUMPTEC KIT PLUNGER SEAL XXX XXX XXX XXX 4 SL 28 KIT B PUMPTEC KIT VALVE O RING XXX XXX XXX XXX 2 SL 28 KIT ...

Page 16: ...6 18 NYLOCK ZINC 2 C 07 9 GRIP FLRTOOL 1 1 2 X 6 1 D 15 2 45 ST ELBOW 1 4 NPT 1 D 41 NIPPLE 1 4 NPT CLOSE BR 1 PART DESCRIPTION QTY F 09 Q C 1 4 PLUG BR SHUT OFF 1 G 23 VALVE KNGSTN STD S BND 1 H 37 JET 11006 E VEE BRASS 1 M 16 5 HOE HANDLE ECONO FLRTL 1 M 16 5A U CLAMP SUPP HOE HNDL EC 1 M 19 5 WAND FLOORTOOL COMP ECONO 1 SC 82 TRIGGER COMP KNGSTN VALVE 1 SE 06 7 47 HOSE 1 4 SOL 47 FLRTL ECO 1 RE...

Page 17: ...5 ST ELBOW 1 4 NPT 1 D 41 NIPPLE 1 4 NPT CLOSE BR 1 F 09 Q C 1 4 PLUG BR SHUT OFF 1 G 23 VALVE KNGSTN STD S BEND 1 PART DESCRIPTION QTY G 23 5 VALVE KNSTN HP S BEND 1 H 02 5 BODY TEE JET 1 4 BRASS 2 H 03 CAP NUT TEE JET BRASS 2 H 18 5 JET 11003 TEE BRASS 2 H 18 7 JET 110015 E TEE BRASS 2 M 16 5 HOE HANDLE ECONO FLRTL 1 M 16 5A U CLAMP SUPP HOE HNDL EC 1 M 20 WAND S BND FLTL COM W HD 1 SC 82 TRIGGE...

Page 18: ...OFF 1 G 04 5 GUIDE VALVE STEM HEX BRASS 1 G 05 5 STEM VALVE SS 4 DETAIL TOOL 1 G 08 5 SPRING VALVE 4 UPH TOOL 1 PART Description QTY GR 2 006N70 O RING 2 006 BUNA 70DR 2 GR 2 011N70 O RING 2 011 BUNA 70DR 1 GR 2 013N70 O RING 2 013 BUNA 70DR 1 H 03 5 CAP NUT TEE JET POLYPRO 1 H 18 8 JET 110015 STD FLAT SPRYTIP PLSTIC 1 J 62 VALVE 4 DETAIL TOOL AS MOLDED 1 J 63 TRIGGER 4 DETAIL TOOL 1 J 64 ELBOW 4 ...

Page 19: ... A RETURN AUTHORIZATION Prior to shipping any part assembly or machine to Cleanmaster a Return Authorization Number must be requested from Cleanmaster and displayed prominently on the outside of all packages containing parts or machines for warranty consideration to be processed and in effect A Return Authorization can be obtained by calling Cleanmaster Service Department at 1 425 775 7276 The mac...

Page 20: ...ith any part s other than genuine Cleanmaster parts will immediately void this and all warranties Filters brass fittings seals o rings and quick disconnects are considered expendable in normal use and are not covered by this warranty Dry cleaning solvents cannot be used in the Raptor This warranty shall not cover any Raptor machine housing part or assembly if there is evidence of misuse alteration...

Page 21: ...nent s with any part s other than genuine Cleanmaster parts will immediately void this and all warranties Filters brass fittings seals o rings and quick disconnects are considered expendable in normal use and are not covered by this warranty Dry cleaning solvents cannot be used in the Raptor This warranty shall not cover any Raptor machine housing part or assembly if there is evidence of misuse al...

Reviews: