FILTRATION

FILTRATION

TABLE OF CONTENTS

2

WWW.CLEANCOMFORT.COM

IO-AMHP-245

INTRODUCTION ................................................. 3

What the Air Cleaner Does .............................................3
Features and Benefits .....................................................3 
How It Works ..................................................................3

INSTALLATION ................................................... 4

Location ..........................................................................4 
Installation Steps ............................................................4
Operating Instructions ....................................................4

MAINTENANCE ..................................................  5
SPECIFICATIONS ................................................. 6
LIMITED WARRANTY .......................................... 8

Proprietary Notice 

This document and the information disclosed herein are 
proprietary data of Daikin North America LLC. Neither 
this document nor the information contained herein shall 
be reproduced, used, or disclosed to others without the 
written authorization of Daikin North America LLC except 
to the extent required for installation or maintenance of 
recipient’s equipment. 

Liability Notice 

Daikin North America LLC does not accept any liability 
for installations of air cleaning equipment installed by 
unqualified personnel or the use of parts/components/
equipment that are not authorized or approved by Daikin. 

Copyright Notice 

Copyright 2015, Daikin North America LLC  
All rights reserved. 

i

 

WARNING!

 

 

Before beginning any installation or modification,  

 

be certain that the main line electrical disconnect  

 

switch is in the OFF position. Unexpected start-up  

 

of system blower may cause serious injury. Tag  

 

disconnect switch with suitable warning labels.

i

 

CAUTION!

 

 

Installation: 

•  Only a heating/air conditioning installer or qualified 

service person should install your air cleaner, unless 
you are completely familiar with the necessary tools, 
equipment and potential hazards involved. If you plan 
to install this air cleaner yourself, please be aware that 
the improper use of any tool can be dangerous. The 
manufacturer will not assume any responsibility for 
failures due to incorrect installation procedures.

•  Homeowners can perform the basic maintenance 

functions of replacing filters.

•  When working on the air cleaner, observe precautions 

in this manual, labels attached to the furnace or air 
handler, and other safety precautions that may apply. 
Follow all safety codes. Wear safety glasses and work 

gloves.

READ AND SAVE THESE INSTRUCTIONS

i

 

WARNING!

 

 

This symbol indicates important instructions. Failure to 

 

heed them can result in serious injury or death.

i

 

CAUTION!

 

 

This symbol indicates important instructions.  

 

Failure to heed them can result in injury or material 

 

property damage.

Our continuing commitment to quality products may  

mean a change in specifications without notice. 

© 2015 DAIKIN NORTH AMERICA LLC 

Houston, Texas • USA

www.cleancomfort.com 

1-800-267-8305 • Fax: 1-416-213-5593

Summary of Contents for AMHP-245

Page 1: ...ON AIR CLEANERS IO AMHP 245 WWW CLEANCOMFORT COM 11 15 IMPORTANT READ AND SAVE THESE INSTRUCTIONS THIS GUIDE TO BE LEFT WITH EQUIPMENT OWNER WHOLE HOUSE TRUE HEPA AIR CLEANER Installation Operation Manual MODEL AMHP 245 i ...

Page 2: ...tart up of system blower may cause serious injury Tag disconnect switch with suitable warning labels i CAUTION Installation Only a heating air conditioning installer or qualified service person should install your air cleaner unless you are completely familiar with the necessary tools equipment and potential hazards involved If you plan to install this air cleaner yourself please be aware that the...

Page 3: ...these air cleaners also help protect and prolong the operating efficiency of the home s heating and cooling equipment Provides a more comfortable environment year round How It Works Return air ducts of heating and cooling systems carry airborne particles back to the heating and cooling equipment of the home Here the particles can be captured by the air cleaner s HEPA filter This AMHP 245 air clean...

Page 4: ...ent air shear inside the duct it is recommended that you install a deflector inside the boot so the discharged air is deflected down into the boot When running the flexible duct make sure that there are no kinks or sharp bends that will impede the airflow from the unit Secure and seal the hose and connections to prevent air leakage 6 It is important to maintain some distance between the inlet and ...

Page 5: ...ctor for these parts iWARNING Make sure to turn the air cleaner OFF before performing any maintenance or removing any components Replacement Parts Note When the filters are new you may notice a new smell from the system This is normal and will dissipate within a few hours Carbon VOC Prefilter Part AMP W3 0855 Replace every three to six months based on conditions in the home If there are heavy odor...

Page 6: ...FM 417 m hr Power Cord 9 0 ft 2 7 m Filter Dimensions Carbon Prefilter 47 x 7 x in 119 x 19 1 x 0 63 cm HEPA Filter 8 H x 14 Dia x 2 in 20 3 x 36 2 x 6 0 cm Carbon VOC Filter optional 26 x 7 x in 67 6 x 19 1 x 1 3 cm Collecting Surface Area Carbon Prefilter 2 45 ft 0 23 m HEPA Filter 65 ft 6 04 m Carbon VOC Filter optional 1 39 ft 0 13 m Whole Home Air Changes Day 1500 ft home 30 air changes day 2...

Page 7: ...FILTRATION IO AMHP 245 WWW CLEANCOMFORT COM 7 NOTES ...

Page 8: ... ANY DISTRIBUTOR DEALER OR OTHER PERSON WHATSOEVER CONSEQUENTIAL OR INCIDENTAL DAMAGES FOR THE BREACH OF ANY WARRANTY WHETHER EXPRESS OR IMPLIED FOR ANY OTHER CONTRACT BREACH OR FOR NEGLIGENCE OR OTHER TORT INCLUDING BUT NOT LIMITED TO LOSSES OF PROPERTY ARISING OUT OF THE FAILURE OF THIS EQUIPMENT TO OPERATE FOR ANY REASON WHATSOEVER ARE EXCLUDED Some states and provinces do not allow limitations...