background image

Page 1 

 

 

 

Operating Instructions RESQUE 100 

Room air purifier with patented Smart E-Filter 

 
 
 

 
 
 
 
Clean Air Enterprise AG 
St. Wendelin 1 
CH-6343 Holzhäusern ZG 
Service Hotline    +41 848 650 650 
E-mail     [email protected] 
Version 6.2.2021 

Summary of Contents for RESQUE 100

Page 1: ... Instructions RESQUE 100 Room air purifier with patented Smart E Filter Clean Air Enterprise AG St Wendelin 1 CH 6343 Holzhäusern ZG Service Hotline 41 848 650 650 E mail info clean air enterprise com Version 6 2 2021 ...

Page 2: ...ings 3 1 2 Notes on operation 4 2 Structure of the unit 5 3 Operating the unit 6 4 Service Plan 7 4 1 Pre filter exchange 7 4 2 Service interval electrostatic filter and activated carbon filter 8 5 Guarantee 8 6 Technical data 8 7 Declaration of conformity 9 ...

Page 3: ...o liability for damage or malfunctions resulting from failure to observe the operating instructions If safety devices of the unit are changed or removed or if the unit is changed without authorisation or used improperly clean air enterprise AG assumes no liability 1 1 Warnings The warning signs attached to the unit must be observed and must not be removed The following warning labels are on the un...

Page 4: ...stallation The air inlet in the upper area must remain free The two air outlets on the side need a minimum distance of 15 cm from the nearest object For optimum performance and room circulation the unit should be placed as centrally as possible and free standing The unit may only be used in closed dry rooms Operation The unit may only be operated by persons who have read and understood the operati...

Page 5: ...In addition there is practically no pressure loss which enables a high volume flow with low power consumption and quiet operation Activated carbon filter Especially on hot summer days with little wind ozone levels regularly exceed the permissible limits source www ozon info ch The activated carbon filter reduces the ozone content in the room to a comfortable level In addition it reliably removes u...

Page 6: ... Freely selectable fan speed 4 On Off Switching the appliance on and off The unit will run for about 60 seconds after it is switched off Tip If the unit is not used for a longer period of time it is recommended to use the main switch on the back as the unit consumes standby power 5 Operating data m3 h Current volume flow rH Relative humidity ppm CO2 concentration CO2 parts per million Fresh air ha...

Page 7: ...close the door Caution Dirt has collected in the pre filter during operation collected in the prefilter Wear respiratory protection when changing the prefilter Do not shake the prefilter and wash your hands thoroughly afterwards 1 2 3 blue side The unit is connected to the mains at the rear The unit can be switched on and off with the main switch When switched off the unit does not need any power ...

Page 8: ... Consequences of normal wear and tear negligent operation incorrect use or third party intervention are not covered by the warranty The warranty also expires if non original spare parts are used 6 Technical data Voltage 230V 50 60 Hz Power consumption 220W Power consumption 1 6 A Weight 70kg Dimensions LxWxH 66 x 37 x 90cm Material housing Steel Filter steps Pre filter G5 Smart E Filter E10 Activa...

Page 9: ...plies with all relevant provisions of the Machinery Directive 2006 42 EC The above mentioned machine fulfils the requirements of the following directives and standards Directive 2006 42 EC Machinery Directives Directive 2014 30 EU on electromagnetic compatibility Harmonised standards applied DIN EN ISO 12100 Safety of machinery DIN EN 60204 1 2019 06 VDE 0113 1 2019 06 VDE 0113 1 2019 06 Safety of...

Reviews: