background image

 

 

 

 

 

Operating Instructions 

 

Before getting started, please remove the 

Clean Air Optima CA-605

 from its box and allow it to 

become accustomed to the room temperature for at least 30 minutes especially if the machine is 
cold from the outside air. The CA-605 is designed to operate at temperatures between 5 -40 ºC 
and relative humidity of less than 80%.  
 
To get started, grasp the water tank by the handle and lift from the base. Next, flip the tank over 
and unscrew and remove the water tank lid and filter. 
 
Then place the water tank under the faucet for filling. Fill the tank with tap water (or other clean 
water source with water temperature under 40ºC), re-insert the lid and filter. Flip the water tank 
once again until it is on the right side up. Ensure that the basin is clean and then carefully place 
the water tank back on the lower body. 
 
Wait a few seconds until the water tank lid starts to release water into the basin. You will hear a 
bubbling sound as the air enters the water tank. Plug the power cord into the electrical outlet 
(NEVER SWITCH ON THE HUMIDIFIER WITHOUT WATER IN THE BASIN). If the humidifier is 
switched off, the power icon should now be red and the values for temperature and humidity will 
now be displayed. 
 
 
Press the 

Power Button 

to activate the humidifier. The machine is now operating in manual mode. 

It will release cool mist on a constant basis with the mist intensity level automatically set to 
medium. The jet at the top of the machine can be rotated to blow mist in different directions. The 
output jets should not be set to spray directly onto people, electrical devices or any obstructions. It 
is best to direct the jet into the open air. 
 
The 

Min/Max Button 

changes the mist level (low, medium, high). This change is displayed on the 

LCD screen by the bars that grow in size.  
 
Pressing the 

Humidity Button 

activates automatic mode (when the LCD display starts to blink the 

word “HUMID”). You can select the desired humidity level by pressing this button repeatedly until 
the required humidity level is displayed (from 45% to 90% in increments of 5%). Once you select 
your desired humidity level, simply stop pressing the button and your humidity level will be set. 
Wait another 5 seconds and the numeric value on the LCD display will switch to the current 
humidity level as measured by the built-in Hygrostat. When the humidity level in the room reaches 
the set humidity level, the machine will go into automatic sleep state and stop producing mist. 
When the room’s actual humidity level drops below your set humidity level about 1-5%, then the 
machine will start producing mist again. 
 
You can deactivate automatic mode very easily by pressing the humidity button until you reach 
90% RH. Press the button one more time and you will now be in manual mode. You will know that 
you are in manual mode because the blinking “HUMID” icon disappears. 
 
Pressing the 

Ion Button 

will activate the negative ion generator and start sending healthy 

negative ions into the air. It will be represented by the tree icon displayed on the LCD screen. 
 
The 

Heating Button 

activates the warm mist feature and is shown on the LCD display with three 

wavy vertical lines. The water is heated in the basin just prior to misting. Please do not place your 
hand over the jet when the warm mist function is activated. The warm mist may raise the 
temperature of the room and may affect the values shown on the display. 
 
The 

Timer Button 

sets the timer. The timer function determines how many hours the humidifier 

will operate. You can set the timer simply by pressing it once for each hour that you would like to 
run the unit. Many people set the timer for 8-9 hours (during their sleep) but it can be set from 1 
hour to 12 hours. As time passes, the time value decreases until it goes to 00:00 and the machine 
shuts off. 
 
If the humidifier should run out of water, you will hear a beeping sound before the machine will 
automatically shut off. The LCD screen will display the 

Empty Water Tank 

icon. 

 

Summary of Contents for CA-605

Page 1: ...1 Ultrasonic Humidifier with Ionizer CA 605 Instruction Manual ...

Page 2: ... not operate the unit without water in the basin Do not insert foreign objects into the device Do not touch the transducer or the lower water basin when the unit is operating Do not scratch the transducer Do not touch the mist output when producing warm mist Do not submerge this device in water Water or cleaning liquids may only be used on parts to be cleaned according to the cleaning and maintena...

Page 3: ...ttom edge of the unit just below our logo Diagram air humidifier CA 605 1 Power Switches the humidifier on off 2 Ion Switches negative ions on off 3 Max Min Sets misting spray level to low medium or high 4 Heating Switches warm mist on off 5 Humidity Sets desired humidity level from 45 to 90 6 Timer Sets the timer to operate the humidifier from 1 to 12 hours 7 Display 8 Mist output jets 9 Water ta...

Page 4: ...ual relative humidity 26 Mist volume indicator low medium and high The Clean Air Optima CA 605 is equipped with a Permanent Reusable White Dust Anti Microbial Filter It consists of an inner cylinder an outer cover and a number of small plastic and ceramic balls The plastic balls are embedded with nano silver an anti microbial agent designed to purify the water and destroy microbes such as bacteria...

Page 5: ...o blink the word HUMID You can select the desired humidity level by pressing this button repeatedly until the required humidity level is displayed from 45 to 90 in increments of 5 Once you select your desired humidity level simply stop pressing the button and your humidity level will be set Wait another 5 seconds and the numeric value on the LCD display will switch to the current humidity level as...

Page 6: ...er basin Remove the water tank Take a machine doesn t work small cup and remove some of the water from the machine s water basin Reinsert the water tank and make sure that it sits properly The volume of spray mist is too Too much mineral scale in the water Clean transducer low basin Water is too dirty or water was kept too Clean the water tank and refill long in the tank with clean water Abnormal ...

Page 7: ... water if your mineral level is still too high 2 If you are using the machine on a daily basis clean the transducer water tank and basin once a week 3 When the water tank needs a refill empty the remaining water from the tank and fill it with fresh water 4 Clean the whole machine and make sure to keep all the parts completely dry when the machine is not in use How to clean the transducer 1 Place 5...

Page 8: ...to 55 relative humidity During the winter months though relative humidity in the average home can drop to below 20 Low humidity can lead to a variety of conditions that cause ill health Dust particles bacteria viruses dust mite feces that are normally trapped by the moist nasal membrane lining in the nose can more easily get into the lungs when the air is dryer and thus reduce the body s natural d...

Page 9: ...fill the tank Large capacity water tank 5L 1 32 US gallons easy refills with normal tap water Runs up to 7 nights or 60 ours without refilling low setting Save money No wicks or filters to replace Low power consumption Applicable for small and larger rooms up to 699 ft 65m 160m Benefits of proper humidification reduces discomfort tiredness sickness reduces susceptibility to colds reduces chapped l...

Page 10: ...ded that the malfunction or damage to the device and or parts occurred under normal operating conditions What is covered All parts defective in material and workmanship For how long Two years from purchase date What we will do Repair or replace any defective parts Exclusions Regular replacement parts such as filter cartridges Other Conditions The provisions of this warranty are in lieu of any othe...