background image

11

Midi-B

5.  SPECIFICATIONS

471

(18.54")

200

(7.87")

Zoom IN

222

(8.74")

Zoom OUT

252

(9.92")

390

(15.35")

362

(14.25")

250

(9.84")

400

(15.75")

Midi-B

POWER SUPPLIES
AC  power  input  Neutrik  PowerCON  True1  100-
240V, 50/60 Hz.

INPUT POWER
700 VA @230Vac - 50Hz.

LIGHT SOURCE
19x Osram 40W RGBW LEDs.
Life: 50000 hrs (L70 20000 hrs).
1900 lumen each LED

OPTICS
4°- 50° Electronic Zoom range.
Max Output: 11000 lumen

CHANNELS
17/21/25/37 control channels.

EFFECTS SECTION
• Preset macro colors.
• 2500K – 8000K color temperature control.
• Electronic strobe from 1flash/sec to 25 flash/sec.
• Three independently controlled LED rings
• Dimmer 16 bit with 4 curves

CONTROL AND PROGRAMMING
• Control signal USITT DMX 512.
• Protocols RDM, WebServer and Art-Net.
• Display Graphic LCD backlit b/w Display.
• Display  battery  Long  life  self-charging  buffer

battery.

• Pan/Tilt Resolution 16 bit.
• Dimmer Resolution 16 bit.
• DMX  signal  connection  5  pole  XLR  input  and

output.

• Ethernet Input.

IP RATING
IP 20 
-  Protected against the entry of solid bodies
larger  than  12mm  (0.47”);  No  protection  against
the entry of liquids.

MOTORS
Stepper  motors,  operating  with  micro-steps,  totally
microprocessor controlled.

MOVING BODY
Movement  by  means  of  two  stepper  motors,
controlled by microprocessor
Automatic  repositioning  of  PAN  and  TILT  after
accidental movement not controlled by control unit.
Travel:
- PAN = 540°
- TILT = 270°

INPUTS
DMX 512 5pin IN & OUT
Art-Net.

ELECTRONICS
• Function reset from the lighting desk.
• “AUTOTEST” function from menu.
• Electronic monitoring with status error.
• Cooling system monitoring.
• DMX level monitoring on all channels.
• Internal data transmission diagnostics.
• Firmware Upgrade via Web Server.
• Firmware upload from another fixture.

NOISE LEVEL
• 42 dBA Theatre Fan mode (background 36.0) 
• 44 dBA SLN Fan mode (background 36.0) 
• 46.5 dBA Auto/Constant Fan mode (background 36.0) 

BODY
• Aluminum and steel structure with plastic covers.
• Two side handles for transportation (Optional).
• Device  locking  PAN  and  TILT  mechanisms  for

transportation and maintenance.

WORKING POSITION
• Working in any position.
• Hanging system: with one fast-lock omega clamp

(1/4 turn) on the base.

SAFETY SPECIFICATIONS
• Max ambient temperature 45°C (113°F).
• Forced ventilation with axial fans.
• Automatic  power  safety  derating  in  case  of

overheat of the LED board.

CE MARKING
In conformity with the European Directives:
• 2014/35/EU  -  Safety  of  electrical  equipment

supplied at low voltage (LVD).

• 2014/30/EU - Electromagnetic Compatibility (EMC).
• 2011/65/EU  -  Restriction  of  the  use  of  certain

hazardous substances (RoHS).

• 2009/125/EC  -  EcoDesign  requirements  for

Energy-related Products (ErP).

ETL
This  product  is  available,  on  demand,  with  cETLus
Listed Mark.

WEIGHT
17 Kg (37.5 lbs).

Summary of Contents for CL3011

Page 1: ...r expectations and requirements INDEX Page Contents 2 1 Safety information 3 2 Unpacking and preparation 4 3 Installation and start up 4 3 1 Installing the fixture 4 3 2 Connecting to manis supply 5 3 3 Connecting the control signal line DMX Art Net 5 3 4 Switching on the fixture and basic SetUp 7 4 Maintenance 7 4 1 Maintenance and Caution 8 4 2 Battery removal 9 4 3 Opening the covers 11 5 Speci...

Page 2: ...r folgendem Link auffindbar www claypaky com Ref FIS022 Safety Information Midi B INFORMACIONES DE SEGURIDAD IMPORTANTE Claypaky recomienda leer detenidamente y conservar la información de seguridad relativa a este producto Además está disponible una versión digital de la misma en el siguiente enlace www claypaky com Ref FIS022 Safety Information Midi B CONSIGNES DE SÉCURITÉ IMPORTANT Claypaky rec...

Page 3: ...45 4 5 45 LOCKED UNLOCKED UNLOCKED LOCKED 90 9 0 9 0 9 0 90 9 0 9 0 9 0 PAN Mechanism Lock and Release every 90 Fig 2 TILT Mechanism Lock and Release every 45 Fig 3 2 3 Packing contents Fig 1 2 x 183102 805 1 2 UNPACKING AND PREPARATION ...

Page 4: ...r on the ceiling or wall WARNING with the exception of when the projector is positioned on the floor the safety cable must be fitted Cod 105041 003 available on request This must be securely fixed to the support structure of the projector and then connected to the fixing point at the centre of the base 3 INSTALLATION AND START UP 3 1 Installing the fixture 3 2 Connecting to manis supply ...

Page 5: ... any possible value that has been modified but not yet confirmed with the Fkey will be cancelled 1 2 Dmx Address Warning Message Fixture ID 8 Connecting to the control signal line DMX Fig 7 Use a cable conforming to specifications EIA RS 485 2 pole twisted shielded 120Ohm characteristic impedance 22 24 AWG low capacity Do not use microphone cable or other cable with characteristics differing from ...

Page 6: ...y will switch off again after a wait time of 30 seconds USING THE MENU 1 Press LEFT D once Main Menu appears on the display 2 Use the UP B and DOWN C keys to select the menu to be used Setup Setup Menu To set the setting options Option Option Menu To set the operating options Informations Informations Menu To read the counters software version and other information Manual Control Manual control Me...

Page 7: ...nds on various factors such as the amount of the effects and the quality of the working environment air humidity presence of dust salinity etc It is recommended that the projector undergoes an annual service by a qualified technician for special maintenance involving at least the following operations General cleaning of internal parts Restoring lubrication of all parts subject to friction using lu...

Page 8: ... B Battery removal Fig 11 This product contains a rechargeable battery To preserve the environment please dispose the battery at the end of its life according to the regulation in force 11 4 2 Battery removal ...

Page 9: ...9 Midi B 2 1 3 4 12 Opening the covers Fig 12 4 3 Opening the covers ...

Page 10: ...10 Midi B 4 3 1 2 13 Cleaning the filters Fig 13 ...

Page 11: ...repositioning of PAN and TILT after accidental movement not controlled by control unit Travel PAN 540 TILT 270 INPUTS DMX 512 5pin IN OUT Art Net ELECTRONICS Function reset from the lighting desk AUTOTEST function from menu Electronic monitoring with status error Cooling system monitoring DMX level monitoring on all channels Internal data transmission diagnostics Firmware Upgrade via Web Server Fi...

Page 12: ...o mains supply LED exhausted or defective Signal transmission cable faulty or disconnected Incorrect addressing Fault in the electronic circuits Lenses broken Dust or grease deposited Check the power supply voltage Call an authorised technician Replace the cables Check addresses see instructions Call an authorised technician Call an authorised technician Clean see instructions 6 CAUSE AND SOLUTION...