12
SCENIUS SPOT
SET UP MENU
DMX ADDRESS
PLEASE NOTE: Without the DMX input signal, the displayed address (DMX Address) blinks.
It lets you select the address (DMX Address) for the control signal. A DMX address between 001 and 512 can be
selected.
CHANNEL MODE
This lets you select the projector operating mode, selecting one of the two available modes:
x
Standard (32 DMX channels occupied,
see DMX-Channel Function)
x
Vector (36 DMX channels occupied,
see DMX-Channel Function
)
FIXTURE ID
It lets you set the “Fixture ID” to be assigned to the projector. An “ID” between 000 and 255 can be assigned.
ETHERNET INTERFACE
It lets you set Ethernet settings to be assigned to the projector as indicated below:
Control Protocol
It lets you select the “Control Protocol” Art-net to be assigned according to the control unit used; the options available are
the following:
x
Disabled:
x
Art-net on IP 2
x
Art-net on IP 10
x
Art-net Custom IP
If the
Control Protocol
option is set on
Disabled
, when an
IP
address (
IP2
,
IP10
or
IP Custom
) is selected, the projector
immediately initializes the
IP
address that was just selected.
If the
Control Protocol
option is enabled (
IP2
,
IP10
or
IP Custom
) and a new one is selected that is different from the
previous one, the projector must be restarted so that it will be correctly initialized.
Repeat on DMX
It lets you enable/disable the transmission of the Ethernet protocol by DMX signal to all the connected projectors.
x
Disabled: DMX transmission disabled.
x
Enabled on primary: DMX transmission enabled.
Universe
It lets you set the “DMX Universe” to be assigned to a series of projectors with values between 000 and 255.
Custom IP Address
It lets you to set the select the “IP Address” Art-net to be assigned, according to the control unit used, with values
between 000 and 255.
Custom IP Mask
It lets you to set the select the “IP Mask” Art-net to be assigned, according to the control unit used, with values between
000 and 255.