MIDI Implementation
Page 95
Performance Dump Request
This message is used for requesting the Nord Lead to transmit one Performance Dump Message. The Mes-
sage Type and Message Specification are used to specify which Performance should be transmitted.
This message is never transmitted
from
the Nord Lead.
▼
If Message Type = 40 (Edit Buffer), the Message Specification should always 0.
▼
If Message Type = 41 or 42, then the Message Specification (00 to 99) corresponds to the Performance
Number (A0 to L9).
All Controllers Request
This message instructs the Nord Lead to send all current Controller values for a specified Slot (see page
70). The message is never transmitted
from
the Nord Lead.
Byte (Hex)
Byte (Decimal)
Description
$F0
240
System Exclusive
$33
51
Manufacturer ID (clavia)
<Device ID>
= Global MIDI Channel. 0 to 15 ($0-$F).
$04
4
Model ID for Nord Lead
$28 or $29
40 to 41
Message Type specifies Performance Edit Buffer (40) or
the PCMCIA card Performance Bank. (41).
$00 or $00-$63
0 or 0 to 99
Message Specification specifies the Performance number,
see below.
$F7
247
End Of Exclusive
Byte (Hex)
Byte (Decimal)
Description
$F0
240
System Exclusive
$33
51
Manufacturer ID (clavia)
<Device ID>
= Global MIDI Channel. 0 to 15 ($0-$F).
$04
4
Model ID for Nord Lead
$14
20
Message Type specifies All Controllers Request.
$00-$03
0 to 3
Message Specification specifies the Program Slot.
$F7
247
End Of Exclusive
Summary of Contents for nord lead
Page 1: ...Owners Manual Software Version 2 x English Clavia DMI AB 1996...
Page 6: ...Page 4 Table Of Contents...
Page 8: ...Page 6 Introduction...
Page 22: ...Page 20 Basic Operations...
Page 74: ...Page 72 MIDI...
Page 90: ...Page 88 About Subtractive Synthesis...
Page 110: ...Page 108 MIDI Implementation Chart...
Page 114: ...112 Index...