4. Control Guide and Connections 

Fig. 6: CH06CPi & CH09i/12i/15i Connections 

Fig. 5: CH06CSi Connections 

4.1 Controls 

All commercial fan heaters are supplied with a remote 

switch  that  provides  the  following  functions:  On/Off, 

Fan, Fan Boost, and Heat.  

 

CH06CSi/CPi:  

The unit is designed to provide 2 levels of heat 

 

CH09i/12i/15i: 

The unit is designed to provide 3 levels of heat. 

 

The remote control box houses 4 single pole switches 

to give the functions listed below figure 4.  

 

 

 

 

 

 

 

 

 

 

 

4.2 

Con-

trolling Multiple Heaters 

 

One control unit can control up to 10 heaters, and 

can control a combination of models. 

 

When  controlling  more  than  one  heater  via  one        

controller, 

connections to the terminals 2, 3, 4 & 5 

must  be  connected  via  isolator  switch.

  In  the   

master heater the 3A fuse (near terminal 4) protecting  

wiring of the switch circuit must be replaced by a fuse 

with  suitable  rating.  For  controlling  up  to  2  heaters 

– 

3A

, up to  4 heaters 

– 5A

, up to 10 heaters - 

13A

 

For more connection details see figures 5 and 6 for 

the CH06CSi and CH06CPi/CH09i/12i/15i models   

respectively. The wiring diagram for controlling multi-

ple heaters is located on page 10. 

 

Fig. 4: Control Unit Switches (Front View) 

Model No 

Heat I 

Heat II 

Heat III 

CH06CSi 

3kW 

6kW 

N/A 

CH06CPi 

3kW 

6kW 

N/A 

CH09i 

3kW 

6kW 

9kW 

CH12i 

4kW 

8kW 

12kW 

CH15i 

5kW 

10kW 

15kW 

Power Output 

CH06CS/CP Control Functions 

On/Off  

(Switch 1) 

Runs fan at a fixed speed, no heat output. 

Fan Boost 

(Switch 1 + 2) 

Runs fan at maximum speed, no heat 

output. 

Heat I  

(Switch 3 or 4) 

Activates half heat setting* 

Heat II 

(Switch 3 + 4) 

Activates full heat setting* 

CH09/12/15 Control Functions 

On/Off  

(Switch 1) 

Runs fan at a fixed speed, no heat output. 

Fan Boost 

(Switch 1 + 2) 

Runs fan at maximum speed, no heat 

output. 

Heat I  

(Switch 3) 

Activates 1/3 heat setting* 

Heat II 

(Switch 4) 

Activates 2/3 heat setting* 

Heat III 

(Switch 3 + 4) 

Activates full heat setting* 

* Intelligent Fan Control enabled. See section 3 for 

details 

Summary of Contents for CH06CPi

Page 1: ...rnton Industrial Estate Milford Haven Pembrokeshire SA73 2RT Tel 01646 692172 Fax 01646 695195 Mon to Thu 8 30am to 4 30pm Fri 8 30am to 3 30pm Email technical consortepl com Web www consortepl com IN...

Page 2: ...utral and earth Electrical supply for the CH06CPi and CH09i 12i models is either 240V single phase or 415V three phase neutral and earth Electrical supply for the CH15i model is 415V three phase neutr...

Page 3: ...lso be connected on a 230 240 volt 50Hz supply The maximum current draw for the 06CPi 09i 12i models are 25A 37 5A and 50A for single phase and approximately 8 3A 12 5A and 16 6A per phase for a three...

Page 4: ...own on Fig 3 Secure the wall bracket to the wall with suitable fix ings Ensure the position of this bracket will allow suitable clearances between the heater when fitted and adjacent walls Minimum of...

Page 5: ...e rating For controlling up to 2 heaters 3A up to 4 heaters 5A up to 10 heaters 13A For more connection details see figures 5 and 6 for the CH06CSi and CH06CPi CH09i 12i 15i models respectively The wi...

Page 6: ...of fan failure or an obstruction of the free airflow by two thermal cut outs If this happens the thermal cut outs effectively switch off the appliance The appliance will not operate until the thermal...

Page 7: ...7 CH06CSi Wiring Diagram 51000214 Iss 01...

Page 8: ...8 CH06CPi Wiring Diagram 51000214 Iss 01...

Page 9: ...9 CH09i 12i 15i Wiring Diagram 51000214 Iss 01...

Page 10: ...10 51000214 Iss 01...

Reviews: