Claudgen CA1509S Installation & Operation Manual Download Page 3

 

 

Mounting 

When mounted over a doorway, the unit should 
be mounted as low as possible and not more than 
3.4 metres above the floor.  A single unit will give 
adequate coverage for a 1.2 metre doorway.  For 
wider doorways, units may be mounted end to 
end.  The heater should be mounted so that the 
inlet or outlet air flows are not obstructed in any 
way.  A clearance of at least 300 mm should be 
maintained around the inlet and outlet grilles. 

Installation  

Having removed the appliance lid, to acquire 
these Instructions, also ensure that the Remote 
Control Switch Box, which is packed inside the ap-
pliance with these Instructions, is removed and 
retained. 
The appliance ‘air flow’ and ‘external dimensions’ 
are shown in Fig 1.   
The heater may be mounted in one of several 
ways i.e:- 

Wall mounting 

1.  Using WALL BRACKETS supplied. 
Onto a suitable vertical wall or bearers, the 2 wall 
brackets are secured at the centres shown in Fig 
2.  The appliance, with 2 upper bolts threaded 
securely into each face, is then fitted on-
to/between the wall brackets as shown in Fig 3.  
The lower fixing bolts are then fitted through each 
wall bracket into each side of the appliance. 
The upper 2 bolts allow the appliance to be 
slipped onto, and held by, the wall brackets.  The 
fitting of the lower bolts in each side locks the ap-
pliance to the brackets. 
Tighten-up securely all 3 bolts in each side. 

 
2.  DIRECTLY to a suitable vertical wall or bearers. 
  Using 4 x No.12 wood screws.  Screw through 
the holes in the appliance case rear, at the cen-
tres shown in Fig 4.  Keyhole slots are provided for 
the upper 2 fixing screws, allowing the appliance 
to be initially located.  The lower 2 fixing screws 
pass through the appliance rear, supporting the 
appliance and preventing any movement up off 
the upper 2 screws. 
  The wall surface to which the appliance is to 
be mounted must be flat to avoid any distortion of 
the appliance casing. 
 

 
 
 

Suspended/hanging 

1.Using Ø20mm CONDUIT. 
The appliance may be suspended by Ø20mm con-
duit via two suitable holes provided in the top of the 
appliance, see Fig 5. 
 
2.  Studding. 
The heater offers four M8 threaded holes as shown in 
Fig 6. from which the appliance may be suspended. 
 There are diagrams showing all of this on the follow-
ing page 

41001304 Iss 01 

Controls

 

The units are designed to provide 2 levels of heat 
i.e half heat and full heat, together with 2 fan 
speeds, normal and boost.  The remote control 
box houses 4 switches. The switch plate wiring is 
shown below, along with a front view.  There is a 
more detailed drawing on the following page. 

The functions of the switches are as follows:- 
SWITCH 1 (left-hand)   

ON/OFF 

SWITCH 2   

 

FAN SPEED CONTROL 

SWITCH 3   

 

½ HEAT ON/OFF 

SWITCH 4   

 

½ HEAT ON/OFF 

Reviews: