3.0 Installation
3.0 Installation
3.1 The site :
Ensure that there is sufficient space for the installation, servicing and easy access to all main
breaker switches / valves (i.e. electricity and water).
Ensure that the surface the appliance is going to be installed onto is adequately stable and capable
of supporting the appliance during normal operation, listed below are the approximate machine
weights when fully laden during normal operation.
C200G, C300G, C500U and C750U must be installed onto a metal stand in accordance with
CSA
168, clause 5.10
(
C
anadian
S
tandards
A
ssociation)
Once installed ensure that the appliance is stable and secure, with its weight being distributed
equally and does not tilt more than 3° in any direction.
If the appliance is being installed onto a stand or table, ensure it is capable of withstanding the ‘Fully
loaded’ weight for the appliance stated below.
3.2 Electrical connection :
All electrical connections MUST be carried out by an authorized technician and in accordance with
local regulations.
As a minimum ‘
Classeq
’ recommends that the following standards are maintained :
•
All appliances must be connected via a circuit breaker or some other protective device,
for the rating of the device refer to either the rating plate on the appliance or the last
page of this manual.
•
Supply breaker switch must have all pole separation of more than 1/8 inch (3mm).
•
The cabinet of the appliance must be grounded, the connection stud is located at the rear of the
appliance (a suitable ring terminal shall be required), this is in addition to the main electric ground.
3.2.1 Electrical rating :
For the electrical rating details, please refer to either the rating plate on the appliance or the last
page of this manual.
Each appliance is designed to run at either 208v or 240v AC, without any modifications, please note
that the ratings between the two voltages do change.
3.2.2 Connection :
The main electrical connection must be made via the field terminal block, which is located :
•
C200G, C500U, C300G and C750U
- Under the top panel, front right hand side of the
appliance.
•
C850P
- Behind the front lower panel, located at the bottom of the control panel.
For supply connections, use copper wires suitable for at least 194ºF (90ºc ), of the following sizes
•
C200G and C500U
minimum wire gauge
= 14 AWG (2.5mm²) minimum gauge
•
C300G, C750U and C850P
= 8 AWG (10mm²) minimum gauge
Machine sizes
Weight
(fully loaded)
Weight
(transport / shipping)
C200G & C500U
198 lbs (90 Kgs)
165 lbs (75 Kgs)
C300G & C750U
298 lbs (135 Kgs)
198 lbs (90 Kgs)
C850P
386 lbs (175 Kgs)
287 lbs (130 Kgs)