7
E
nglish
Test Data
Commission Regulation (EC) No 1275/2008 Requirement
Mode
Ecodesign requirements, from 7 January 2013
Result - Remark
Verdict
Off mode
Power consumption in ‘off mode’:
Power consumption of equipment in any off-mode
condition shall not exceed 0.50 W
0.0002 kW
P
Standby mode
Power consumption in ‘standby mode(s)’:
The power consumption of equipment in any
condition providing only a reactivation function, or
providing only a reactivation function and a mere
indication of enabled reactivation function, shall
not exceed 0.50 W.
0.0002 kW
p
The power consumption of equipment in any con-
dition providing only information or status display,
or providing only a combination of reactivation
function and information or status display shall not
exceed 1.00 W.
N/A
Seasonal space heating energy efficiency
Description
Value
Seasonal space heating energy efficiency in active mode-
η
S,on
40 %
For electric local space heaters-
η
th
100 %
The electric to primary energy
“
conversion coefficient”-CC
2.5
F
(1) is a correction factor accounting for a positive contribution to the seasonal space
heating energy efficiency of electric storage local space heaters due to adjusted
contributions for options for heat storage and output; and a negative contribution to
seasonal space heating efficiency for commercial local space heaters due to adjusted
contributions for options for the heat output, expressed in %;
0.0 %
F
(2) is a correction factor accounting for a positive contribution to the seasonal space
heating energy efficiency due to adjusted contributions of controls of indoor heating
comfort, the values of which are mutually exclusive, cannot be added to each other,
expressed in %;
6.0 %
F
(3) is a correction factor accounting for a positive contribution to the seasonal space
heating energy efficiency due to adjusted contributions of controls for indoor heating
comfort the values of which can be added to each other, expressed in %;
0.0 %
F
(4) is a correction factor accounting for a negative contribution to the seasonal space
heating energy efficiency by auxiliary electricity consumption, expressed in %;
0.0 %
F
(5) is a correction factor accounting for a negative contribution to the seasonal space
heating energy efficiency by energy consumption of a permanent pilot flame, expressed in %.
0.0 %
Seasonal space heating energy efficiency-
η
S
36 %
Verdict
p