12
Parts & Service: 020 8988 7400 / E-mail: [email protected] or [email protected]
CHARGING MORE THAN ONE BATTERY
1. Simultaneous multiple charging
should be carried out in series
since this enables monitoring of
the current circulating in each
battery.
2. If two batteries with rated
voltages of 12V are connected in
series, set up the charger using
the positive cable connected to
the 24V terminal.
RAPID CHARGING USING THE TIMER
1. The WBC400 has a charge timing device of up to 60 minutes operation.
2. To initiate Rapid Charging, turn
the fast-charge timer to the
required charging time in minutes
and turn the charging level rotary
switch to one of the fast charging
levels of either 4, 5 or 6.
3. When the pre-set time has
elapsed the current is
automatically switched off.
4. Turn the charging level rotary
switch to the off position.