SPECIFICATIONS

Capacity

10 Tonne

Dimensions

Operating Pressure 10000 PSI

A

110 mm

Ram Travel

183 mm

B

340 mm

Ram Diameter

42 mm

C

365 mm

Net Weight

55 kg

D

180 mm

E

183 mm

F

600 mm (ex pump)

G

450 mm

H

1070 mm

L

80 mm

Summary of Contents for STRONG-ARM CSA10BB

Page 1: ...WARNING Read these instructions before using the machine OPERATION MAINTENANCE INSTRUCTIONS GC0913 10 TONNE HYDRAULIC BENCH PRESS MODEL NO CSA10BB PART NO 7614020 ...

Page 2: ...s intended Faulty goods should be returned to their place of purchase no product can be returned to us without prior permission This guarantee does not effect your statutory rights SAFETY PRECAUTIONS During assembly or if the press is moved always call for the help of an assistant do not manhandle single handedly Always bolt the press down to a suitably strong bench Ensure the press is located on ...

Page 3: ...ories such as arbor plates be certain they are centered below the ram and are in full contact with the bed Parts being pressed may splinter shatter or be ejected from the press Due to varied applications it is your responsibility to always use adequate guards wear eye protection and protective clothing when operating this press Keep hands and fingers away from parts that may pinch and shift Failur...

Page 4: ... open to the elements Severe weather conditions will damage the hydraulic components 1 Attach the feet to the frame using the nuts bolts and washers 2 With the help of an assistant lift the frame assembly upright and manoeuvre it to its intended location on the workbench 3 Insert the ram through the hole in the base plate and secure in position using the locking collar 1 x Frame 1 x Pump 2 x Base ...

Page 5: ...ylinder Seal the thread with PTFE tape ensuring it is tight when the gauge is facing the front of the press 6 Attach the pump assembly to the frame using the fixing bolts and washers Fit one bolt first to bear the weight and use the adjustment provided by the upper bolt The pump can be installed on either side of the frame but will usually be assembled for a right handed press operator 7 Screw the...

Page 6: ...required position Then set the bed frame in position on the pins HYDRAULIC PUMP RAM OPERATION 1 Before using the press purge any air from the system by opening the release valve by turning it anti clockwise and pumping several full strokes to eliminate any air bubbles Tight the release valve before continuing 2 Check all parts are secure and correctly aligned before using the press The press is no...

Page 7: ...d as shown Secure the pressure cap by tightening the grub screw with a suitable hex key If one of the mandrels is required the adaptor must be fitted instead of the pressure cap Secure the adaptor by tightening the grub screw with a suitable hex key Select your mandrel depending upon the size of the workpiece bearing surface The mandrel can then be pushed into the adaptor where the built in spring...

Page 8: ...osed 3 Pump the handle to bring the ram very lightly into contact with the workpiece 4 Manoeuvre the workpiece so that the desired point of contact is directly beneath the centre of the ram 5 When satisfied that the workpiece is correctly aligned and is completely stable in that position slowly pump the handle so that the ram begins to exert pressure on the workpiece Continue to pump the handle wh...

Page 9: ... store it with the ram piston withdrawn and the operating handle in the lowered position to protect the moving parts PERIODICALLY Check the press frame to make sure all bolts are tight and inspect for cracked welds bent loose or missing parts Check the hydraulic connections for leaks Replace or properly repair any damaged or leaking hydraulic components before using In the event of leaking seals o...

Page 10: ...t lower completely Air lock in system Open the release valve and remove the oil filler plug Pump the handle a couple of full strokes and close the release valve Replace the filler plug Pump will not deliver pressure Reservoir could be over filled or have low oil level Check oil level by removing the filler plug and topping up to the correct level Pump feels hesitant under load Pump cup seal could ...

Page 11: ...ional com or Service clarkeinternational com SPECIFICATIONS Capacity 10 Tonne Dimensions Operating Pressure 10000 PSI A 110 mm Ram Travel 183 mm B 340 mm Ram Diameter 42 mm C 365 mm Net Weight 55 kg D 180 mm E 183 mm F 600 mm ex pump G 450 mm H 1070 mm L 80 mm ...

Page 12: ...12 Parts Service 020 8988 7400 E mail Parts clarkeinternational com or Service clarkeinternational com FRAME PARTS DIAGRAM ...

Page 13: ...d Frame Assembly 23 Nut 10mm 11 Lower Collar 24 Mandrell Adaptor Set Complete 12 Arbor Plate 25 Mandrell Mounting Bracket part of adaptor kit 13 Bolt M8 x 16 socket head 26 Frame Foot RAM PARTS NO DESCRIPTION NO DESCRIPTION R1 Bolt M20 x 25 R14 O Ring R2 Sealing Washer R15 Threaded End R3 Connecting Insert R16 Spring R4 Gauge Coupling R17 Nut M8 R5 Dust Cap R18 Ring 29 5 x 3 55 R6 Connector R19 Ra...

Page 14: ...14 Parts Service 020 8988 7400 E mail Parts clarkeinternational com or Service clarkeinternational com RAM PARTS DIAGRAM ...

Page 15: ...15 Parts Service 020 8988 7400 E mail Parts clarkeinternational com or Service clarkeinternational com DECLARATION OF CONFORMITY ...

Page 16: ......

Reviews: