TROUBLESHOOTING
Problem
Probable Cause
Remedy
Pump will not work.
Dirt on valve seat/warn
seals.
Bleed pump unit or have
unit overhauled with new
seals.
Pump will not produce
pressure.
Pump feels hesitant
under load.
Pump will not lower
completely.
Air-lock in system.
Open the release valve
and remove the oil filler
plug. Pump the handle a
couple of full strokes and
close the release valve.
Replace the filler plug.
Pump will not deliver
pressure.
Reservoir could be over-
filled or have low oil level.
Check oil level by
removing the filler plug
and topping up to the
correct level.
Pump feels hesitant
under load.
Pump cup seal could be
worn out.
Have the cup seal
replaced.
Pump will not lower
completely.
Air-lock in system.
Release air by removing
the filler plug.