background image

IMPORTANT

:

Before use, ensure the water supply is of adequate volume for your
needs, e.g., if you use a water butt - ensure it contains sufficient water.

Detergents

Fig.4.

Fuel

Unscrew the fuel filler cap (C, Fig.4), and
fill the tank with diesel fuel using an
appropriate size funnel.

If you intend to use the chemical
injection facility, drop the end of the
filter take-up hose, situated at the rear
of the machine and which is fitted with
a filter, into the detergent cannister.

NOTE:
If the filter is loose, ensure it is attached
to the end of the detergent pick-up hose
before use.

Use ONLY those detergents specifically
designed for use with Power Washers.
We recommend the use of CLARKE
Traffic Film Remover, which is a powerful
low foaming agent for car cleaning,
patio cleaning etc., or CLARKE Wash &
Wax, both available from your CLARKE
dealer.

Ensure the detergent is mixed according
to the manufacturers instructions.

See ‘Operation’ for additional
infor mation regarding the use of
detergents.

Fig.5.

Dilute the detergent according
to manufacturers instructions

8

WARNING: DO NOT USE PETROL

13

MOTOR THERMAL OVERLOAD

Should the motor overheat, the motor thermal
overload will intervene.

Allow at least three mins., then remove the main
cover and press the reset button, located
beneath the main ON/OFF switches, protected
by a  transparent cover, shown in Fig 18.

Whilst carrying out this operation, check the
serviceability of the 1amp fuse, adjacent to the
reset button.

Fig.18.

HEATING OVERLOAD

Fig.17.

Should the machine overheat, the thermal
overload will intervene.

Allow at least three mins. before removing the
main cover, unscrewing the protective cap,
on the side of the main junction box,  arrowed
in Fig 17, and  pressing the reset button.

NOTE: The reset buttons will only activate once the temperatures reduce to a safe level. This
should normally take 3 mins. or so, but could be longer depending upon circumstances.
Should the machine stil fail to start, following the reset procedures, then the problem is likely
to be more serious. Contact your Clarke dealer

Summary of Contents for Power Wash KING 135

Page 1: ...OPERATING MAINTENANCE INSTRUCTIONS 0702 KING 135 HOT WASHER Part No 7320512 KING 135 HOT WASHER...

Page 2: ...that the details and specifications contained herein are correct at the time of going to print However CLARKE International reserve the right to change specifications at any time without prior notice...

Page 3: ...look forward to it giving you long and satisfactory service GUARANTEE This CLARKE product is guaranteed against faulty manufacture for a period of 12 months from the date of purchase Please keep your...

Page 4: ...when using the chemical injection facility 9 Never use the chemical injection facility to introduce solvents e g paint hinners petrol oil etc 10 Do not operate the machine whilst standing on ladders u...

Page 5: ...ed on Motor hums when switched on and does not start Motor cuts out Additives are not being supplied Motor operates but no hot water Air in system Worn high pressure nozzle Pressureregulatorincorrectl...

Page 6: ...used as indicated by marking or colour code 4 Replacement fuse covers can be obtained from your local dealer or most electrical stockists EXTENSION CABLES If an extension cable is used always ensure i...

Page 7: ...tly assemble the hose bracket to the frame using the 4 screws and nuts provided CAUTION The water inlet connection is directly above the diesel fuel filler cap Ensure the connection is completely leak...

Page 8: ...on for additional information regarding the use of detergents Fig 5 Dilute the detergent according to manufacturers instructions 8 WARNING DO NOT USE PETROL 13 MOTOR THERMAL OVERLOAD Should the motor...

Page 9: ...pulled This will ease and assist the subsequent restarting of the motor as pressure will remain equalised on either side of the pump thereby reducing the load on the motor when restarting NEVER attem...

Page 10: ...the unit to O OFF Allow the pump to run for a minute or so until the water being ejected is cold then switch OFF the pump by pressing the switch to O OFF If the chemical injection facility has been u...