BEFORE USE

If the compressor has not been used for 24 hours or more, open the drain valve 
to drain any condensate which may have accumulated. See page 8

CHECK THE OIL LEVEL

The compressor is supplied without any 
oil inside.

1. Make sure that the oil level is half 

way up the oil sight glass.

2. If not, remove the oil cap and top 

up the reservoir.

• Only use SAE30 compressor oil, 

available from your Clarke 
Dealer   

 

Part No. 3050801).

ATTACH AIR TOOLS

Attach the air hose to the regulator  
(if fitted).

WARNING: BEFORE CONNECTING ANY AIR TOOLS, MAKE SURE YOU 
HAVE READ ANY INSTRUCTIONS SUPPLIED WITH THE  TOOL, ALSO ENSURE 
THAT THE TOOL IS COMPATIBLE WITH THE COMPRESSOR AND HOSE 
SPECIFICATIONS.

Summary of Contents for PED14A100

Page 1: ...OPERATION MAINTENANCE INSTRUCTIONS 0112 3HP DIRECT DRIVE COMPRESSOR MODEL NO RAIDER 55 RAIDER 100 RAIDER 105 PART NO 2225800 2225805 225810...

Page 2: ...keep your receipt which will be required as proof of purchase This guarantee is invalid if the product is found to have been abused or tampered with in any way or not used for the purpose for which i...

Page 3: ...rials e g cellulose paint ensure that there is adequate ventilation and keep clear of any possible source of ignition 11 Before spraying any material always consult paint manufacturers instructions fo...

Page 4: ...of this product do not correspond with the markings on the terminals of your plug proceed as follows The wire which is coloured Blue must be connected to the terminal which is marked N or coloured Bl...

Page 5: ...or The ON OFF switch is in the OFF pressed down position MOVING THE AIR COMPRESSOR Before moving the compressor switch off and disconnect it from the mains power supply Always use the handle Do not li...

Page 6: ...at the oil level is half way up the oil sight glass 2 If not remove the oil cap and top up the reservoir Only use SAE30 compressor oil available from your Clarke Dealer Part No 3050801 ATTACH AIR TOOL...

Page 7: ...compressor will restart automatically whenever the pressure in the main tank falls below a certain level 3 Check the safety valve daily by pulling on the ring attached Air should be released you pull...

Page 8: ...e compressor air tank unattended while under pressure Always release the pressure from the tank when not in use or prior to storage as described in the following section DRAINING THE TANK 1 Turn the c...

Page 9: ...th a thermal overload device which operates as a safety device to protect the motor When the motor overheats for any reason the overload cutout automatically cuts the power thereby preventing damage t...

Page 10: ...take filter should be inspected on a MONTHLY basis and more often in dusty conditions 1 Air Filter Cover Pull the filter cover away from the compressor as shown 2 Air Filter Remove the sponge filter f...

Page 11: ...100 RAIDER 105 Max Pressure 8 Bar 116 psi 8 Bar 8 Bar 116 psi Air Displacement 14 5 CFM 14 5 CFM 14 5 CFM Receiver Capacity 50 L 100 L 100 L Fuse Rating 13 A 13 A 13 A Dimensions L x W x H mm 820 x 4...

Page 12: ...sket blown or valve broken 1 Wait for compressor to cool down 2 Disassemble head gasket 3 Replace any broken components 4 Carefully clean all sealing surfaces before reassembling If in doubt contact Y...