11
CHECK THE NON RETURN VALVES (EVERY 6 MONTHS)
If the tank pressure decreases for no apparent reason, it is possible that the
non-return valve is leaking. To check, ensure the tank is not under pressure and
the machine switched OFF.
1. Examine the non-return valve,
and replace the gasket and valve
if necessary.
SPECIFICATIONS
RAIDER 50
RAIDER 100
RAIDER 105
Max.Pressure
8 Bar, 116 psi
8 Bar
8 Bar, 116 psi
Air Displacement
14.5 CFM
14.5 CFM
14.5 CFM
Receiver Capacity
50 L
100 L
100 L
Fuse Rating
13 A
13 A
13 A
Dimensions (L x W x H) mm
820 x 420 x 740
1100 x 570 x 820
1165 x 420 x 1050
Guaranteed Sound Power Level
97 dB(A)
97 dB(A)
Weight
46 kg
60 kg
55 kg
Compressor Oil
SAE 30
SAE 30
SAE 30
Please note that the details and specifications contained herein, are correct at
the time of going to print. We reserve the right to change specifications at any
time without prior notice.