background image

4

GENERAL SAFETY RULES 

WORK AREA 

1.

Keep the work area clean and well lit

. Cluttered and dark areas invite accidents. 

2.

Do not operate log splitters in explosive atmospheres, such as in the presence of 
flammable liquids, gases or dust.

 Log splitters create sparks which may ignite the dust or 

fumes. 

3.

Keep children and bystanders away while operating the log splitter.

 Distractions can 

cause you to lose control. 

4.

The surface must be perfectly level to prevent the machine from moving during operation.

ELECTRICAL SAFETY 

1.

The log splitters plug must match the outlet. Never modify the plug in any way.  

Unmodified plugs and matching outlets will reduce risk of electric shock.

2.

Avoid body contact with earthed or grounded surfaces such as pipes, radiators, ranges 
and refrigerators.

 There is an increased risk of electric shock if your body is earthed or 

grounded.

3.

Do not expose log splitters to rain or wet conditions.

 Water entering a log splitters will 

increase the risk of electric shock.

4.

Do not abuse the cord. Never use the cord for carrying, pulling or unplugging the log 
splitter. Keep cord away from heat, oil, sharp edges or moving parts.

 Damaged or 

entangled cords increase the risk of electric shock.

5.

When operating the log splitter outdoors, use an extension cord suitable for outdoor use.

 

Use of a cord suitable for outdoor use reduces the risk of electric shock. 

6.

Do not leave the log splitter unattended when plugged in to the mains supply

.

 

PERSONAL SAFETY 

1.

Stay alert, watch what you are doing and use common sense when operating a log 
splittter. Do not use the log splitter while you are tired or under the influence of drugs, 
alcohol or medication. 

A moment of inattention while operating log splitters may result in 

serious personal injury. 

2.

Use safety equipment. Always wear eye protection.

 Safety equipment such as non-skid 

safety shoes, close fitting clothing and suitable work gloves should always be used.

3.

Avoid accidental starting. Ensure the switch is in the off position before plugging in

4.

Do not overreach. Keep proper footing and balance at all times. 

This enables better 

control of the log splitters in unexpected situations. 

5.

Dress properly. Do not wear loose clothing or jewellery. Keep your hair, clothing and 
gloves away from moving parts. 

Loose clothes, jewellery or long hair can be caught in 

moving parts. 

WARNING: READ ALL INSTRUCTIONS. FAILURE TO FOLLOW ALL 
INSTRUCTIONS LISTED BELOW MAY RESULT IN ELECTRIC SHOCK, FIRE AND/
OR SERIOUS INJURY. SAVE THESE INSTRUCTIONS. 

Summary of Contents for LOGBUSTER 6

Page 1: ...OPERATION MAINTENANCE INSTRUCTIONS 10 08 LOG SPLITTER MODEL NO LOGBUSTER 6 PART NO 3402035...

Page 2: ...s guaranteed against faulty manufacture for a period of 12 months from the date of purchase Please keep your receipt which will be required as proof of purchase This guarantee is invalid if the produc...

Page 3: ...safety rules 4 Additional safety rules for log splitters 5 Safety symbols 7 Electrical connections 8 Identification of parts 9 Assembly 10 Operation 12 Maintenance 16 Troubleshooting 17 Disposal 17 S...

Page 4: ...ged or entangled cords increase the risk of electric shock 5 When operating the log splitter outdoors use an extension cord suitable for outdoor use Use of a cord suitable for outdoor use reduces the...

Page 5: ...yourself and that of others around you 1 Never tamper with the log splitter or attempt to operate the machine without covers Do not allow split logs to accumulate always clean up as you work accumulat...

Page 6: ...er than 5 seconds as the pump may be damaged by the oil overheating This could occur when the wood being split is excessively fibrous knotty or wet green wood NOTE A small log can be difficult to spli...

Page 7: ...7 SAFETY SYMBOLS...

Page 8: ...CK If this appliance is fitted with a plug which is moulded onto the electric cable i e non rewireable please note 1 The plug must be thrown away if it is cut from the electric cable There is a danger...

Page 9: ...s LGLOGB611 3 Split wedge LGLOGB603 12 Base LGLOGB612 4 Control levers connection bracket LGLOGB604 13 Star knob LGLOGB613 5 Top motor shield LGLOGB605 14 Side bracket for support table LGLOGB614 6 Pl...

Page 10: ...sher and nut supplied 3 Follow the same steps to install the other arm assembly FITTING THE WHEELS 1 Slide one of the wheels onto the axle followed by a washer 2 Slide the axle through the holes on th...

Page 11: ...o position The star knob can be fitted on either side of the bracket MOVING THE LOG SPLITTER To move the log splitter to the work site 1 Make sure the oil tank cover air bleeder is fully tightened 2 G...

Page 12: ...ily and will not jam as frequently as green wood Make sure the logs do not twist rock or slip while being split Break log in the direction of its growing grain Do not attempt to split 2 logs at the sa...

Page 13: ...lic oil 1 Lift up the flap on the switch housing to access the on off buttons 2 Press the ON button I to turn the logbuster on 3 Press the OFF button 0 to turn the logbuster off 4 In an emergency pres...

Page 14: ...the splitting action Releasing either lever stops the splitting wedge Releasing both levers will return the splitting wedge to its original position NOTE Once you start splitting the log do not reach...

Page 15: ...he logs being split 2 Release one control lever and then switch off the motor The ram will remain in its current position 3 Ram Travel Adjusting Rod Locking Screw Release the locking screw 4 Raise ram...

Page 16: ...T Only use CLARKE HYDRAULIC OIL available from your nearest dealer Part No 1Ltr 3050830 5Ltr 3050835 3 Clean the neck of the oil tank and replace the oil tank cover air bleeder 4 Run the log splitter...

Page 17: ...ile the motor is running Air bleeder is not open Open oil bleeder Control levers are bent Repair the bent control levers Low oil level Check and refill hydraulic oil Log splitter works but with abnorm...

Page 18: ...50 mm A weighted Sound Pressure Level dB A 71 dB A Log Capacity Maximum Length 1050 mm Minimum Length 550 mm Maximum Diameter 320 mm PARTS AND SERVICING For Parts Servicing please contact your nearest...

Page 19: ...19 DECLARATION OF CONFORMITY...

Page 20: ......

Reviews: