USING THE 12 VOLT POWER SUPPLY

Two cigarette lighter type sockets allow connection to DC electrical 
equipment via a standard DC adapter.

USING THE INVERTER 

To protect the battery from damage, this unit has a low-voltage protection 
function which means when the voltage falls below a certain value, it will 
sound an alarm, then turn off automatically. 

It also incorporates short-circuit protection, if the device being powered 
develops a short-circuit fault, the inverter turns off automatically.

1. Set the inverter switch to the 

INVERTER position.

2. Plug the electrical equipment into 

the 230V AC outlet.

3. Start electrical equipment.

4. The battery level is indicated by 

the inverter power indicator lights.

5. If the inverter fails, the inverter 

status light illuminates.

6. If the inverter fails suddenly, for example, there is a short circuit, check the 

fuse and replace if required.

WARNING: BE AWARE THAT A FULLY CHARGED 12V BATTERY CAN HAVE 
AN OUTPUT OF APPROX.13.5V. CONSULT THE APPLIANCE HANDBOOK TO 
ENSURE IT IS SAFE TO OPERATE FROM A 12V BATTERY.

WARNING: WHEN USING THE INVERTER FUNCTION THE JS5IN1 AND 
WHATEVER YOU ARE POWERING MUST BE INSIDE AWAY FROM ANY RAIN 
OR MOISTURE.

WARNING: THE INVERTER OUTPUT VOLTAGE IS 230V 50HZ, (MAX 300W). 

CAUTION: MAKE SURE THAT THE APPLIANCE BEING CONNECTED IS IN 
GOOD WORKING ORDER. IF IT BEGINS TO ACT ABNORMALLY OR STOPS 
SUDDENLY, DISCONNECT IT FROM THE JUMPSTART.

CAUTION: MAKE SURE THE APPLIANCE DOES NOT EXCEED THE MAXIMUM 
RATED LOAD FOR THE JUMPSTART.

CAUTION: ANY DEVICE WHICH CONTAINS AN INDUCTIVE LOAD E.G. 
DEVICES THAT CONTAIN A MOTOR MAY REQUIRE MORE CURRENT ON 
START UP.

Summary of Contents for JS5IN1

Page 1: ...OPERATION MAINTENANCE INSTRUCTIONS LS0212 5 IN 1 JUMP START MODEL NO JS5IN1 PART NO 6240005...

Page 2: ...for a period of 12 months from the date of purchase Please keep your receipt which will be required as proof of purchase This guarantee is invalid if the product is found to have been abused or tamper...

Page 3: ...age do not exceed our recommendations for duration of jump starting 6 The unit is NOT designed to be used as a replacement for a vehicle battery 7 NEVER allow the battery to become completely discharg...

Page 4: ...ut conductor to the unearthed battery terminal first then connect the BLACK negative conductor to a suitable earthing point on the chassis well away from any fuel lines 19 ALWAYS wear suitable protect...

Page 5: ...com SAFETY SYMBOLS Class II appliance Always read instructions before use Electrical Hazard due to exposed live terminals Chemical Hazard from battery acid USB Port Live centre pin Suitable for indoor...

Page 6: ...arging Indicators 2 Pressure Gauge 11 USB Sockets 5V DC Outlet 3 Air Compressor On Off Switch 12 Air Compressor Hose Compartment 4 Worklight 13 Charging Jack Socket 5 Polarity Indicator Light 14 Inver...

Page 7: ...OM THE BATTERY Charge this unit before using it for the first time Recharge after every use if possible and thereafter once every three months Always avoid leaving the unit in a state of discharge For...

Page 8: ...engine should then be started The state of charge of the internal battery can be checked by disconnecting the lighter plug lead and then depressing the battery status button This method will only part...

Page 9: ...OPERATION USING THE USB POWER SUPPLY 1 Insert the USB cable into one of the USB sockets on the side of the unit 2 Press the USB side of the INVERTER USB switch as shown This will supply a maximum 5V...

Page 10: ...cted the correct way round the polarity indicator light will turn Green If you connect the leads the wrong way round the polarity indicator light will turn Red If the battery is completely discharged...

Page 11: ...locking lever through 90 degrees 4 Switch the air compressor ON using the switch shown The air pressure will be indicated by the pressure gauge Pump up the tyre to the required pressure 5 Switch OFF...

Page 12: ...is indicated by the inverter power indicator lights 5 If the inverter fails the inverter status light illuminates 6 If the inverter fails suddenly for example there is a short circuit check the fuse a...