background image

10

Parts & Service: 020 8988 7400 / E-mail: [email protected] or [email protected]

JUMP STARTING

ALWAYS carry out the following preliminary checks:

• Switch off the vehicle ignition and ALL ancillary equipment - lighting, 

radio etc.

• Ensure the vehicle battery is rated at 12V and is not damaged in any 

way.

• Ensure the area is well ventilated.

• Ensure the battery terminals are clean and the clamps are firm and 

secure.

• Remove vehicle battery filler plugs and check electrolyte level. If 

necessary, top up with distilled water.

When completely satisfied, proceed as follows:

1. Connect the red clamp to the unearthed battery terminal first, (this is 

usually the positive (+ve) terminal and painted RED), then the black clamp 
to the chassis or engine bolt, well away from the fuel lines or moving parts, 
ensuring the connections are firm and secure.

• Do not allow the two leads to touch each other.

• When the leads are connected the correct way round the polarity 

indicator light will turn Green.

• If you connect the leads the wrong way round the polarity indicator 

light will turn Red.

• If the battery is completely discharged, the polarity sensor will not be 

able to detect the polarity of the battery, and will prevent activation 
of the jumpstart.

2. Switch the vehicle ignition ON, and leave in this condition FOR APPROX 

TWO MINUTES. (This will provide the vehicle battery with a short ‘boost’ 
charge to allow for easier starting).

3. Switch the ignition to ‘start’, for NO MORE than 6 seconds. If the engine 

does not start, within this time, SWITCH OFF the ignition and wait for at least 
3 minutes before trying again.

4. Once the engine is running, disconnect the BLACK clamp FIRST i.e. that 

connected to the chassis or engine bolt etc., and return it to its storage 
position, then disconnect the RED clamp, from the battery terminal, and 
restore to its storage position.

WARNING: IT IS POSSIBLE THAT SOME ELECTRONIC EQUIPMENT COULD BE 
DAMAGED BY JUMP STARTING. ALWAYS CHECK WITH THE CAR 
MANUFACTURER’S HANDBOOK TO DETERMINE WHAT PRECAUTIONS IF 
ANY SHOULD BE TAKEN.

Summary of Contents for JS5IN1

Page 1: ...OPERATION MAINTENANCE INSTRUCTIONS LS0212 5 IN 1 JUMP START MODEL NO JS5IN1 PART NO 6240005...

Page 2: ...for a period of 12 months from the date of purchase Please keep your receipt which will be required as proof of purchase This guarantee is invalid if the product is found to have been abused or tamper...

Page 3: ...age do not exceed our recommendations for duration of jump starting 6 The unit is NOT designed to be used as a replacement for a vehicle battery 7 NEVER allow the battery to become completely discharg...

Page 4: ...ut conductor to the unearthed battery terminal first then connect the BLACK negative conductor to a suitable earthing point on the chassis well away from any fuel lines 19 ALWAYS wear suitable protect...

Page 5: ...com SAFETY SYMBOLS Class II appliance Always read instructions before use Electrical Hazard due to exposed live terminals Chemical Hazard from battery acid USB Port Live centre pin Suitable for indoor...

Page 6: ...arging Indicators 2 Pressure Gauge 11 USB Sockets 5V DC Outlet 3 Air Compressor On Off Switch 12 Air Compressor Hose Compartment 4 Worklight 13 Charging Jack Socket 5 Polarity Indicator Light 14 Inver...

Page 7: ...OM THE BATTERY Charge this unit before using it for the first time Recharge after every use if possible and thereafter once every three months Always avoid leaving the unit in a state of discharge For...

Page 8: ...engine should then be started The state of charge of the internal battery can be checked by disconnecting the lighter plug lead and then depressing the battery status button This method will only part...

Page 9: ...OPERATION USING THE USB POWER SUPPLY 1 Insert the USB cable into one of the USB sockets on the side of the unit 2 Press the USB side of the INVERTER USB switch as shown This will supply a maximum 5V...

Page 10: ...cted the correct way round the polarity indicator light will turn Green If you connect the leads the wrong way round the polarity indicator light will turn Red If the battery is completely discharged...

Page 11: ...locking lever through 90 degrees 4 Switch the air compressor ON using the switch shown The air pressure will be indicated by the pressure gauge Pump up the tyre to the required pressure 5 Switch OFF...

Page 12: ...is indicated by the inverter power indicator lights 5 If the inverter fails the inverter status light illuminates 6 If the inverter fails suddenly for example there is a short circuit check the fuse a...

Page 13: ...t be carried out by qualified service technicians STORAGE When not in use store in a safe dry place SPECIFICATIONS Please note that the details and specifications contained herein are correct at the t...

Page 14: ...14 Parts Service 020 8988 7400 E mail Parts clarkeinternational com or Service clarkeinternational com DECLARATION OF CONFORMITY...

Page 15: ...15 Parts Service 020 8988 7400 E mail Parts clarkeinternational com or Service clarkeinternational com NOTES...

Page 16: ......

Reviews: