CLEANING AND MAINTENANCE

WARNING: MAKE SURE THAT THE PUMP IS DISCONNECTED FROM THE
MAINS SUPPLY BEFORE  CLEANING, OR PERFORMING ANY
MAINTENANCE.

• The pump should require no maintenance other than regular

cleaning. Its’ mechanical seal is lubricated in an oil chamber, and its’
bearings are ‘sealed for life’. If the pump starts to show signs of wear
or damage, contact your CLARKE dealer for advice.

• Do not use the pump if there is any damage to the mains supply

cable, or to the float switch or its cable.

• Check the pump installation regularly to ensure  the base inlet is clear

of leaves or other debris.

• Do not attempt to repair the pump yourself, as you may damage the

seals and invalidate your guarantee.  Repairs must be carried out by
a qualified pump engineer, your CLARKE dealer, or contact the
CLARKE Service Department on:  020 8988 7400.

If the pump becomes badly clogged, the stainless steel strainer may be
removed and cleaned by removing the three screws 

FROM THE BASE ONLY

.

DO NOT attempt to remove any other screws.

Backflush the pump chamber by directing a jet of clean water through the
outlet port.

WARNING: DO NOT ATTEMPT TO STRIP THE PUMP FURTHER AS THIS WILL
INVALIDATE THE GUARANTEE.

ANNUALLY OR EVERY 2000 WORKING HOURS

 (Whichever is sooner)

The sealing oil must be checked by a qualified pump engineer. Consult your Clarke
dealer, or Clarke International Service Department.

Summary of Contents for IVP14A

Page 1: ...SUBMERSIBLE WATER PUMP MODEL No IVP14A Part No 7230095 OPERATION MAINTENANCE INSTRUCTIONS 08 08...

Page 2: ...pump GUARANTEE This product is guaranteed against faulty manufacture for a period of 12 months Please keep your receipt as proof of purchase This guarantee is invalid if the product is found to have...

Page 3: ...from tanks or rivers excavations flooded underpasses etc NOTE Whenever the pump is used to pump contaminated water e g to drain fish ponds you must ALWAYS immerse the pump in clean water and run it f...

Page 4: ...s likely to shift 9 If pumping water which is liable to freeze the pump MUST be run continuously otherwise the pump must be removed from the water and stored in a frost free location 10 If the pump is...

Page 5: ...this appliance may not correspond with the coloured markings identifying terminals in your plug proceed as follows Connect GREEN YELLOW cord to plug terminal marked with a letter E or Earth symbol or...

Page 6: ...6 PARTS IDENTIFICATION Handle Pump Base Float Switch Outlet Connector...

Page 7: ...vailable from your Clarke dealer LOCATING THE PUMP 1 Tie a rope to the lifting handle of the pump and lower the pump on a flat surface in the area that you want to drain If there is sediment in the op...

Page 8: ...loat switch which automatically switches the pump ON when the water is above a predetermined level 3 The pump will begin to drain water As the water level falls so will the float switch until it stops...

Page 9: ...debris Do not attempt to repair the pump yourself as you may damage the seals and invalidate your guarantee Repairs must be carried out by a qualified pump engineer your CLARKE dealer or contact the...

Page 10: ...s s e c e n s a n a e l c d e k c o l b t o n s i r e n i a r t s e r u s n e o t k c e h C y r a s s e c e n s a r a e l c d e t c u r t s b o r o d e g g o l c e b u t e g r a h c s i D o o t r e t...

Page 11: ...stances The Following Standards have been applied to the product EN 292 1 EN 292 2 EN 55014 1 2001 EN 55014 2 1997 EN 60555 2 3 EN 60335 1 EN 60335 2 41 The technical documentation required to demonst...

Page 12: ...12...

Reviews: