Clarke IVP14A Operation & Maintenance Instructions Manual Download Page 7

7

PREPARATION

CONNECT THE DELIVERY HOSE

WARNING: DISCONNECT THE PUMP FROM THE MAINS POWER SUPPLY
BEFORE CONNECTING THE DELIVERY HOSE

The pumps  outlet connecter  is provided with a 2” BSP Male thread, for
connection to a suitable adapter (not provided). It is advisable to seal the
thread with PTFE, or similar tape, to ensure maximum performance from your
pump.

Where it is necessary for long horizontal stretches of delivery hose to be used,
the hose ID should be greater than that of the delivery outlet.

NOTE: When the pump is used in a permanent or semi-permanent

installation, a check valve MUST be fitted in the  delivery pipe.

NOTE: Suitable hoses are available from your Clarke dealer.

LOCATING THE PUMP

1

Tie a rope to the lifting handle of the pump and lower the pump on a flat
surface in the area that you want to drain.

• If there is sediment in the operating area, the pump should be

placed on house bricks, or similar.

• Ensure the pump is positioned with adequate space so that the

movement of the float switch is not restricted.

NOTE: The symbol  

 on the pumps’ Rating Plate, denotes the

MAXIMUM depth to which the pump may be submerged, in
metres.

• The pump should be well clear of silt, mud or any type of marine

growth.

• Take all necessary precautions as described on page 4 before

plugging in, and switching ON.

WARNING: NEVER CARRY THE PUMP USING THE MAINS POWER CABLE.
DAMAGE TO ELECTRICAL CABLES CAN BE DANGEROUS. ALWAYS USE THE
LIFTING HANDLE OR A ROPE ATTACHED TO THE LIFTING HANDLE WHEN
MOVING THE PUMP.

Summary of Contents for IVP14A

Page 1: ...SUBMERSIBLE WATER PUMP MODEL No IVP14A Part No 7230095 OPERATION MAINTENANCE INSTRUCTIONS 08 08...

Page 2: ...pump GUARANTEE This product is guaranteed against faulty manufacture for a period of 12 months Please keep your receipt as proof of purchase This guarantee is invalid if the product is found to have...

Page 3: ...from tanks or rivers excavations flooded underpasses etc NOTE Whenever the pump is used to pump contaminated water e g to drain fish ponds you must ALWAYS immerse the pump in clean water and run it f...

Page 4: ...s likely to shift 9 If pumping water which is liable to freeze the pump MUST be run continuously otherwise the pump must be removed from the water and stored in a frost free location 10 If the pump is...

Page 5: ...this appliance may not correspond with the coloured markings identifying terminals in your plug proceed as follows Connect GREEN YELLOW cord to plug terminal marked with a letter E or Earth symbol or...

Page 6: ...6 PARTS IDENTIFICATION Handle Pump Base Float Switch Outlet Connector...

Page 7: ...vailable from your Clarke dealer LOCATING THE PUMP 1 Tie a rope to the lifting handle of the pump and lower the pump on a flat surface in the area that you want to drain If there is sediment in the op...

Page 8: ...loat switch which automatically switches the pump ON when the water is above a predetermined level 3 The pump will begin to drain water As the water level falls so will the float switch until it stops...

Page 9: ...debris Do not attempt to repair the pump yourself as you may damage the seals and invalidate your guarantee Repairs must be carried out by a qualified pump engineer your CLARKE dealer or contact the...

Page 10: ...s s e c e n s a n a e l c d e k c o l b t o n s i r e n i a r t s e r u s n e o t k c e h C y r a s s e c e n s a r a e l c d e t c u r t s b o r o d e g g o l c e b u t e g r a h c s i D o o t r e t...

Page 11: ...stances The Following Standards have been applied to the product EN 292 1 EN 292 2 EN 55014 1 2001 EN 55014 2 1997 EN 60555 2 3 EN 60335 1 EN 60335 2 41 The technical documentation required to demonst...

Page 12: ...12...