background image

15

Parts & Service: 020 8988 7400 / E-mail: [email protected] or [email protected]

DECLARATION OF CONFORMITY

Summary of Contents for DEVIL 4000

Page 1: ...OPERATION MAINTENANCE INSTRUCTIONS ORIGINAL INSTRUCTIONS GC0618 ISS 4 PROPANE GAS HEATER MODEL NO DEVIL 4000 PART NO 6926150...

Page 2: ...guarantee is invalid if the product is found to have been abused or tampered with in any way or not used for the purpose for which it was intended Faulty goods should be returned to their place of pur...

Page 3: ...th the heater Inspect the hose assembly before each use of the heater If there is excessive abrasion or wear or hose is cut replace with the hose assembly listed on the parts list before using the hea...

Page 4: ...onoxide CO is toxic Pregnant women persons with a heart or lung condition anaemia or under the influence of alcohol or those at high altitude are more likely to be effected by Carbon Monoxide CO can b...

Page 5: ...The BROWN wire must be connected to the terminal which is marked L or coloured red The YELLOW AND GREEN wire must be connected to the terminal which is marked E or or coloured green We strongly recom...

Page 6: ...rom the heat IN THE EVENT OF A GAS LEAK 1 Extinguish all smoking materials and other open flames 2 Do NOT operate electric switches or light matches 3 Close all supply valves on gas tank or cylinder 4...

Page 7: ...d steady the heater during assembly 2 Attach the lower frame and secure using six of the machine screws provided 3 Attach the handle to the lower frame and secure using four machine screws 4 Slide the...

Page 8: ...he chart 2 Move straight up to time of operation desired left side 3 Read the cylinder size required Always use full cylinders with good air circulation and no frost on the cylinders CONNECTING THE GA...

Page 9: ...setting 4 Set the thermostat to the required setting The heater will turn off and on automatically as the air temperature varies in the heater area HEATER SHUT DOWN 1 Securely close the valve on the p...

Page 10: ...ICING A hazardous condition may result if a heater is used that has been modified or is not functioning properly When the heater is working properly The flame is contained within the heater The flame...

Page 11: ...e Bottle Pressure Minimum Pressure 1 4 Bar Regulator Output 20 PSIG 0 14MPa Electrical Input 220 240V 50Hz Ignition Direct Spark Primary Flame Control Solid State 10 15 Sec timing Operating Temperatur...

Page 12: ...12 Parts Service 020 8988 7400 E mail Parts clarkeinternational com or Service clarkeinternational com EXPLODED VIEW...

Page 13: ...l Mounting Bracket 11 Motor Assembly 39 Control Box CRTL Panel 12 Grille Inlet 40 Male Fitting Conn 1 4 MPT x 1 4 SAE FLR 13 Machine Screw SS 41 Set Screw Nyloc 14 Burner Outer Plate 42 Control Box In...

Page 14: ...14 Parts Service 020 8988 7400 E mail Parts clarkeinternational com or Service clarkeinternational com WIRING DIAGRAM...

Page 15: ...15 Parts Service 020 8988 7400 E mail Parts clarkeinternational com or Service clarkeinternational com DECLARATION OF CONFORMITY...

Page 16: ......

Reviews: