27
Renewing Motor Brushes
WARNING!
ENSURE THE PLUG IS DISCONNECTED FROM THE POWER SUPPLY BEFORE PROCEEDING
•
Lower the blade to minimum height and remove the riving knife and blade guard.
•
Turn the table saw over so that it rests on its table top .
1.
Remove the bottom grill by removing the 6 screws shown.
2.
Unscrew and remove the brush caps, (one either side of the motor housing), then withdraw the
brush with springs attached.
3.
Carefully insert replacement brushes and replace the screw on caps.
•
Always replace both brushes at the same time.
Fig.32