OVERLOAD CUT-OUT
Your table saw features an OVERLOAD CUTOUT device, so that if the motor overheats (due to feed pressure
being too great, a dull blade or low voltage etc.), the motor will automatically cut out. In this event,
1.
Switch the machine OFF by pressing the red button ‘O’,
2.
Unplug the machine from the mains supply and allow the machine to cool for three to five
minutes before plugging in and attempting to restart.
Note the time taken to reset may be longer, depending upon ambient temperature etc.
WARNING!
THE MACHINE MUST BE IN THE OFF POSITION, AND THE PLUG REMOVED FROM THE POWER
SOURCE WHILST COOLING DOWN TAKES PLACE. THIS PREVENTS ACCIDENTAL STARTING WHEN
THE RESET BUTTON IS PUSHED, AS THE NO VOLT RELEASE WILL NOT HAVE TRIPPED .
ADJUSTMENTS
Fig.14
CHANGING THE BLADE HEIGHT
Turn the blade height handwheel ‘A’ Fig. 14, to
adjust the height of the blade.
•
Turn the blade height adjuster handwheel,
clockwise to lower the blade and
anticlockwise to raise the blade.
Fig.15
CHANGING THE BLADE ANGLE
Release the blade angle locking lever ‘B’ Fig 15,
by pulling the lever outwards.
•
Grasp the blade angle adjustment wheel
‘A’ and move the complete assembly in
the direction of the arrow in Fig. 15, so that
the pointer is aligned with the desired
angle as shown on the angle indicator .
•
Lock the blade at the desired angle by
pressing the locking lever ‘B’ firmly inwards.