13
3.
Slide the Riving Knife into position, and adjust the Riving knife so that a clearance of no more than
5mm exists between blade and knife, and along the full length of the riving knife, as illustrated in Fig. 5
Note:
Make sure that the Riving Knife is directly in line with the blade at all times. If at any time it
becomes misaligned, it must be straightened before the table saw is used.
5.
When satisfied, tighten the riving knife securing bolt before replacing the Table Insert.
D
FITTING THE BLADE GUARD
1.
Raise the saw blade as far as possible.
Fig.6
4.
Tighten the riving knife securing bolt as shown in
Fig. 6.
Fig.7
2.
Attach the Blade Guard to the Riving Knife, as
shown.
•
The guard should be secure, but still be capable of
dropping under its own weight. Do not over
tighten.
✘
✘ ✔
Fig.5