CDM-20 Page-17
4.3 AC VOLTAGE
Range
Accuracy
Resolution
200mV
±1.2 % of rdg + 3 digits
100µV
2V
1 mV
20V
±0.8 % of rdg + 3 digits
10mV
200V
l00mV
700V
±1.2% of rdg + 3 digits
1V
Input Impedance:
10M
Ω
on all ranges.
Frequency Range:
40Hz to 1 kHz; Indication: Average (rms of sine wave).
Overload Protection:
250V rms AC for 200mV range and 1000V DC or 700V rms AC for other ranges.