![Clarke CAG232 Operating & Maintenance Instructions Download Page 10](http://html1.mh-extra.com/html/clarke/cag232/cag232_operating-and-maintenance-instructions_2614878010.webp)
10
After every 50 hours of use.
Unscrew Carbon Brush Caps, withdraw the Carbon
Brushes and check their condition. They must be
replaced when they have worn down to 6mm in
length. If they are found to be serviceable, blow the
brush holder clean with low pressure compressed air,
and replace. Take care to avoid damaging the spring
or wire when changing brushes.
MAINTENANCE
I
MPORTANT: Before carrying out any maintenance tasks, ALWAYS disconnect
the tool from the mains electrical supply.
Before Each Use
1.
Always inspect the tool before use, and ensure it is in top condition.
2.
Ensure air vents are clear, use compressed air at low pressure, to clean the tool
where possible. (Always wear protective goggles when using compressed air).
3.
Check the power cable to ensure it is sound and free from cracks, bare wires etc.
4.
Ensure the grinding wheel or cutting disc is perfectly sound, free from cracks
or damage in any way. Replace the disc when it is worn to 150mm diameter,
or if it is chipped or cracked. Never use the grinder with a damaged disc.
Only fit replacement discs with an outside diameter of 230mm (9”), and a
bore of 22mm. If in doubt, consult your dealer.
The gearbox and motor are lubricated during manufacture, and further lubrication
is not normally needed.