- 13 -
Unusual noise from
compressor.
Bolts loose.
Flywheel loose.
Unit installed on an unsuitable
base.
Bearings, piston rings or cylinder
worn.
Valve broken.
Compressor
becomes too hot.
Contact Clarke Service
Department
Insufficient ventilation.
Oil level too low (check 2 or 3
times after stopping).
Fault in valves (machine not
stopping).
Not fully unloading
Load genie partly blocked.
Clean cooling fins and suction
filter.
Blown head gasket (machine
not stopping).
Dirt on cooling fins or suction
filter.
Unit working at too high a
pressure.
Contact Clarke Service
Department
Contact Clarke Service
Department
Contact Clarke Service
Department
Connect to a supplementary
compressor or install a larger
model.
See that sufficient air is supplied to
flywheel or fan of compressor and
that hot air is properly vented.
Fill with oil – see Page 10.
Tighten bolts - see page 16.
Tighten flywheel.
Move unit to a more solid base.
Contact Clarke Service
Department
Contact Clarke Service
Department
Compressor being
overworked and running
continuously.
Contact Clarke Service
Department
Summary of Contents for Air SP15ND
Page 1: ...1 Operating Maintenance Instructions 1110 Air Compressor ENGINE DRIVEN...
Page 5: ...5 Fig 1...
Page 9: ...9 PUMP PARTS...
Page 15: ...15 Notes...
Page 16: ......