USING THE PUMP

CAUTION!

CHECK THE PUMP FOR DAMAGE BEFORE USE, DO NOT USE THE PUMP IF IT IS

DAMAGED IN ANY WAY

1

Place the pump on a flat surface in the area that you want to drain.

If there is sediment in the operating area, the pump should be placed on
house bricks, or similar.

Ensure the pump is positioned with adequate space so that the movement of
the float switch is not restricted - recommended minimum area of 40 x 40cm

ALWAYS raise and lower the pump using a rope attached to the lifting handle.

Take all necessary precautions as described on page 4 before plugging in, and
switching ON.

WARNING!

NEVER CARRY THE PUMP USING THE MAINS POWER CABLE. DAMAGE TO

ELECTRICAL CABLES CAN BE DANGEROUS. ALWAYS USE THE HANDLE WHEN

MOVING THE PUMP.

2

Connect the mains plug to a high sensitivity residual current device (RCD) which
has a tripping current of less then 30mA.

3

Switch the mains power supply on,

The pump incorporates a float switch, which automatically switches the pump
ON when the water is above a pre-determined level.

4

The pump will begin to drain water.

 • As the water level falls, so will the float switch, until it stops the pump.

5

When the pumping is finished, disconnect the pump from the mains power supply

The pump is fitted with a thermal cut out to protect the motor from
overheating. If the thermal cut out activates, the motor will automatically
switch back on when it has cooled down sufficiently.

CAUTION!

DO NOT ALLOW THE PUMP TO RUN DRY.

Summary of Contents for 7260065

Page 1: ...DIRTY WATER PUMP DIRTY WATER PUMP MODEL No LVP1A Part No 7260065 OPERATION MAINTENANCE INSTRUCTIONS LS1109...

Page 2: ...chase no product can be returned to us without prior permission This guarantee does not effect your statutory rights RECOMMENDED USES The recommended uses for this pump are Drainage after flooding The...

Page 3: ...entification 6 Preparation 7 Using the pump 8 Cleaning and maintenance 9 Troubleshooting 10 SPECIFICATIONS Motor 230V 50Hz Motor Output 350W Head Max 5 m Maximum Imersion Depth 5 m Maximim Flow Rate 1...

Page 4: ...Have the pump repaired by a qualified person DO NOT ABUSE THE MAINS LEAD Never carry the pump by the mains lead Never pull the mains lead to disconnect the pump from the mains socket Keep the mains le...

Page 5: ...terminal marked with a letter N or coloured BLACK If this appliance is fitted with a plug which is moulded onto the electric cable i e non rewireable please note 1 The plug must be thrown away if it i...

Page 6: ...6 PARTS IDENTIFICATION Handle Pump Base Float Switch Elbow Multi Hose Adaptor May be supplied fitted to the pump 1 Hose 1 BSP 1 Hose Air Bleed Valve...

Page 7: ...hose connector to the required size and attach a suitable hose using with a worm drive clip For maximum efficiency we strongly recommend that you connect a 1 diameter hose to the multi hose adapter A...

Page 8: ...ING THE MAINS POWER CABLE DAMAGE TO ELECTRICAL CABLES CAN BE DANGEROUS ALWAYS USE THE HANDLE WHEN MOVING THE PUMP 2 Connect the mains plug to a high sensitivity residual current device RCD which has a...

Page 9: ...any other repairs must be carried out by your CLARKE dealer or contact the CLARKE Service Department on 020 8988 7400 Check the pump regularly to ensure the base is clear of leaves or other debris Rep...

Page 10: ...h t e g n u l P e h t n i d e p p a r t r i a y n a e v o m e r o t g n i r e w o l t s l i h w m e t s y s r e l l e p m I e h t e c a l p e R d e g a m a d e b y a m r e l l e p m I p o t s t o n l...

Page 11: ...e been applied to the product BS EN 55014 1 2001 A1 A2 BS EN 55014 2 1997 A1 BS EN 61000 3 3 1995 A1 BS EN 61000 3 2 2000 The technical documentation required to demonstrate that the products meet the...

Page 12: ......

Reviews: