Clarke 723100 Operation & Maintenance Instructions Manual Download Page 7

7

Parts & Service: 020 8988 7400 / E-mail: [email protected] or [email protected]

SETTING UP AND USING THE PUMP

POSITIONING THE PUMP

1. Place the pump on a flat surface in the area that you want to drain.

• If there is sediment in the operating area, the pump should be placed 

vertically on house bricks or similar.

• Ensure the pump is positioned with adequate space so that the 

movement of the float switch is not restricted - recommended minimum 
area of 50 x 50cm.

• ALWAYS raise and lower the pump using a rope attached to the lifting 

handle.

• Take all necessary precautions as described on page 3.

USING THE PUMP

1. Connect the mains plug to the mains supply.

• Always use a high sensitivity residual current device (RCD) which has a 

tripping current of less then 30mA.

2. Switch the mains power supply on.

• The pump will begin to drain water.

• As the water level falls, so will the float switch, until it stops the pump.

• You can adjust the position at which the float switch lead clips to the 

side of the pump. Adjusting the length of the float switch lead will 
change the depth of water at which the pump will turn on or off.

3. When pumping is finished, disconnect the pump from the mains power 

supply.

IMPORTANT: Do not allow the pump to run dry.

WARNING: CHECK THE PUMP FOR DAMAGE BEFORE USE, DO NOT USE THE 
PUMP IF IT IS DAMAGED IN ANY WAY.

WARNING: THE WATER BEING PUMPED WILL BE POLLUTED IF THIS PUMP 
BECOMES DAMAGED AND LUBRICANT WITHIN THE PUMP ESCAPES.

Summary of Contents for 723100

Page 1: ...OPERATION MAINTENANCE INSTRUCTIONS GC0818 iss 3 ORIGINAL INSTRUCTIONS SUBMERSIBLE WATER PUMP MODEL NO CSE400A PART NO 723100...

Page 2: ...fety and that of others around you and to help you achieve long and trouble free service from your pump GUARANTEE This product is guaranteed against faulty manufacture for a period of 12 months from t...

Page 3: ...r use and incorporate a cable suitable for use with Class I appliances 12 Disconnect the pump from the electrical supply and wear gloves during servicing or maintenance PUMP SPECIFIC 1 Do not pump exp...

Page 4: ...t be connected to the terminal which is marked N or coloured black The BROWN wire must be connected to the terminal which is marked L or coloured red The YELLOW AND GREEN wire must be connected to the...

Page 5: ...he maximum depth to which this pump should be submerged is 8 Metres This pump is suitable for permanent or semi permanent installations e g installations where it is necessary to maintain a water at a...

Page 6: ...laced in a vertical position on a solid flat surface If this is not available sit the pump on house bricks or something similar and ensure that this type of support is not likely to shift The pump sho...

Page 7: ...Connect the mains plug to the mains supply Always use a high sensitivity residual current device RCD which has a tripping current of less then 30mA 2 Switch the mains power supply on The pump will be...

Page 8: ...e CLARKE Service Department on 020 8988 7400 Note that the pump is fitted with an automatic thermal overload protection device If the pump overheats due to an obstruction in the pump or pumping warm w...

Page 9: ...lt your local Clarke dealer or Clarke International Spare Parts Department Voltage 230V 50Hz Outlet Thread Diameter 1 25 BSP Outlet Hose Adaptor Diameter 1 25mm 1 5 2 19mm 3 4 3 13mm 1 2 Motor output...

Page 10: ...evented from moving 7 If the pump still fails to start consult your CLARKE dealer for advice PUMP WILL START BUT NOT PUMP 1 Check that the inlet is not blocked 2 Check that the outlet is not clogged o...

Page 11: ...11 Parts Service 020 8988 7400 E mail Parts clarkeinternational com or Service clarkeinternational com DECLARATION OF CONFORMITY...

Page 12: ......

Reviews: