INSTALLATION & OPERATION

The pump is complete with an Outlet Hose Adapter which simply screws into 
the outlet port on the side of the pump body.

The adapter has three steps, providing the option for three different hose sizes 
to be used. (See specifications for details).

Please bear in mind, that if the pump is to be used for drainage purposes, or in 
situations that demand maximum efficiency, you should ALWAYS connect the 
largest diameter hose possible to the outlet hose adapter, as small diameter 
hoses reduce capacity and put additional strain on the motor.

Once you have decided upon a suitable hose size, the smaller diameter steps 
of the adapter should be cut off, so as not to cause an obstruction to flow. If 
you subsequently need to install a larger diameter hose, replacement 
adapters are available from your Clarke dealer.

Ensure the hose is secured with a suitable worm drive clip (not supplied).

The pump is completely submersible and must be placed in a vertical position 
on a solid flat surface. If this is not available, sit the pump on house bricks, or 
something similar, and ensure that this type of support is not likely to shift.

The pump should be well clear of silt, mud or any type of marine growth.

IMPORTANT: ALWAYS raise and lower the pump using a rope attached to the 
handle, NEVER by the power cable or float switch cable.

Ideally the pump should be placed in a sump which has adequate dimensions 
so as not to restrict the movement of the float switch.

Please note that the symbol  V  on the pumps’ Rating Plate, denotes the 

MAXIMUM 

depth to which the pump may be submerged, in metres.

With the pump properly installed, and taking all necessary precautions as 
described on page 3, plug in to the mains supply, and switch ON.

NOTE:

If the pump does not deliver immediately, it is possible that an air lock 
exists. Leave the pump for approximately one minute in order for air in 
the pump to vent through the vent valve. If necessary, switch ON and 
Off again in order to assist the venting process.

SUITABLE HOSE, and SPARE/REPLACEMENT HOSE ADAPTERS ARE AVAILABLE 
FROM YOUR CLARKE DEALER

CAUTION: THE WATER BEING PUMPED WILL BE POLLUTED IF THIS PUMP 
BECOMES DAMAGED AND LUBRICANT WITHIN THE PUMP ESCAPES

.

Summary of Contents for 723100

Page 1: ...OPERATION MAINTENANCE INSTRUCTIONS GC0818 iss 3 ORIGINAL INSTRUCTIONS SUBMERSIBLE WATER PUMP MODEL NO CSE400A PART NO 723100...

Page 2: ...fety and that of others around you and to help you achieve long and trouble free service from your pump GUARANTEE This product is guaranteed against faulty manufacture for a period of 12 months from t...

Page 3: ...r use and incorporate a cable suitable for use with Class I appliances 12 Disconnect the pump from the electrical supply and wear gloves during servicing or maintenance PUMP SPECIFIC 1 Do not pump exp...

Page 4: ...t be connected to the terminal which is marked N or coloured black The BROWN wire must be connected to the terminal which is marked L or coloured red The YELLOW AND GREEN wire must be connected to the...

Page 5: ...he maximum depth to which this pump should be submerged is 8 Metres This pump is suitable for permanent or semi permanent installations e g installations where it is necessary to maintain a water at a...

Page 6: ...laced in a vertical position on a solid flat surface If this is not available sit the pump on house bricks or something similar and ensure that this type of support is not likely to shift The pump sho...

Page 7: ...Connect the mains plug to the mains supply Always use a high sensitivity residual current device RCD which has a tripping current of less then 30mA 2 Switch the mains power supply on The pump will be...

Page 8: ...e CLARKE Service Department on 020 8988 7400 Note that the pump is fitted with an automatic thermal overload protection device If the pump overheats due to an obstruction in the pump or pumping warm w...

Page 9: ...lt your local Clarke dealer or Clarke International Spare Parts Department Voltage 230V 50Hz Outlet Thread Diameter 1 25 BSP Outlet Hose Adaptor Diameter 1 25mm 1 5 2 19mm 3 4 3 13mm 1 2 Motor output...

Page 10: ...evented from moving 7 If the pump still fails to start consult your CLARKE dealer for advice PUMP WILL START BUT NOT PUMP 1 Check that the inlet is not blocked 2 Check that the outlet is not clogged o...

Page 11: ...11 Parts Service 020 8988 7400 E mail Parts clarkeinternational com or Service clarkeinternational com DECLARATION OF CONFORMITY...

Page 12: ......

Reviews: