Parts & Service: 020 8988 7400 / E-mail: [email protected] or [email protected]

4. ALWAYS use an approved cable extension suitable for the power rating of 

the pump (see specifications). The conductor size should also be at least 
the same size as that on the pump, or larger. When using a cable reel, 
always unwind the cable completely.

5. ALWAYS maintain the pump with care and keep it clean.

6. NEVER use for pumping flammable liquids or corrosive chemicals. These 

pumps are designed to pump water only.

7. NEVER abuse the electrical cable. Never use the cable for pulling or 

unplugging the pump. Damaged or tangled cables increase the risk of 
electric shock.

8. NEVER run the pump dry. Always ensure the pump is immersed in water 

before starting. Switch the pump OFF immediately WHEN the task is 
completed

9. NEVER pump water from a swimming pool when there is a person or animal 

still in the pool.

10. NEVER install the pump on sand, silt or mud which is likely to shift or 

collapse.

11. NEVER modify this pump in any way. Use it only for the purpose for which it 

is designed.

12. NEVER allow the pump to run dry or operate out of the water.

13. Submersible pumps should always be submerged and stored vertically.

14. Disconnect the pump from the mains supply before placing it into or 

removing it from the water.

15. NEVER insert your fingers into the pump whilst it is connected to the mains.

16. Keep the pump clear of any sediment by standing it on a platform or brick 

or suspending it at a suitable depth.

17. DO NOT use the pump if the water is liable to freeze, as this can cause 

damage to the pump. Remove the pump from the water and store it in a 
frost free location.

SERVICING & REPAIRS

1. ALWAYS have the pump serviced by your local CLARKE dealer, using only 

identical replacement parts. This will ensure the safety of the pump is 
maintained. The use of non standard parts could be hazardous.

2. NEVER attempt any repairs yourself unless suitably qualified. If you have a 

problem with the pump contact your local CLARKE dealer.

3. ALWAYS disconnect the pump from the electrical supply before placing it 

into, or removing from the water, and before any cleaning or 
maintenance.

Summary of Contents for 7230296

Page 1: ...OPERATION MAINTENANCE INSTRUCTIONS GC08 22 ORIGINAL INSTRUCTIONS 560W PUDDLE RESIDUE PUMP MODEL NO CPRP560 PART NO 7230296...

Page 2: ...mp The pump is provided with a thermal overload cut out so that in the event that the pump becomes overheated due to becoming blocked etc it will shut off automatically When the blockage has been clea...

Page 3: ...ce 020 8988 7400 E mail Parts clarkeinternational com or Service clarkeinternational com OVERVIEW FEATURES 1 Water inlet screen 2 Power cable with plug 3 Outlet hose adaptor 4 Lifting handle Pump Perf...

Page 4: ...the pump 3 NEVER direct the water discharge towards electrical wiring or equipment 4 ALWAYS store the pump out of reach of children and do not allow persons unfamiliar with these instructions to opera...

Page 5: ...lapse 11 NEVER modify this pump in any way Use it only for the purpose for which it is designed 12 NEVER allow the pump to run dry or operate out of the water 13 Submersible pumps should always be sub...

Page 6: ...in accordance with the WEEE regulations in relation to the treatment recycling recovery and environmentally sound disposal of the WEEE In effect this means that this product must not be disposed of w...

Page 7: ...in the power cable do not agree with the markings on the plug proceed as follows The BLUE wire must be connected to the terminal marked N or coloured black The BROWN wire must be connected to the ter...

Page 8: ...re not likely to collapse Never position the pump on sand silt mud or ground which is likely to collapse 3 Keep the pump clear of sediment by standing it on a platform or brick or suspending from a ro...

Page 9: ...r may be seen escaping from the discharge hose 4 Disconnect from the power supply when the water has been pumped out Avoid running the pump continuously if the discharge hose has become obstructed and...

Page 10: ...it should be flushed through with clean water before storage 5 When the pump is not being used for extended periods clean and dry it thoroughly and store in indoors if the pump is left in water it sho...

Page 11: ...onnect from the mains supply and remove any objects that may be obstructing the impeller 6 If the pump still fails to start consult your CLARKE dealer PUMP WILL START BUT NOT PUMP 1 Check that the inl...

Page 12: ...12 Parts Service 020 8988 7400 E mail Parts clarkeinternational com or Service clarkeinternational com COMPONENT PARTS...

Page 13: ...he purpose for which it was intended Faulty goods should be returned to their place of purchase no product can be returned to us without prior permission This guarantee does not effect your statutory...

Page 14: ...14 Parts Service 020 8988 7400 E mail Parts clarkeinternational com or Service clarkeinternational com DECLARATION OF CONFORMITY UK...

Page 15: ...15 Parts Service 020 8988 7400 E mail Parts clarkeinternational com or Service clarkeinternational com DECLARATION OF CONFORMITY EU...

Page 16: ......

Reviews: