4
Parts & Service: 020 8988 7400 / E-mail: [email protected] or [email protected]
sharp edges or moving parts. Damaged or tangled cables increase the risk
of electric shock.
3. Keep the mains cable well away from any machinery and ensure an
adequate electrical supply is close at hand so that the operation is not
restricted by the length of the cable.
4. ALWAYS disconnect from the mains supply before moving the heater, or
performing any cleaning or maintenance tasks.
5. Inspect the mains cable regularly for signs of damage. DO NOT use if it is
damaged, and ALWAYS keep it away from the source of heat.
6. Check the heater for damage before use. DO NOT use if the halogen
tubes are damaged or broken. Any damage should be properly repaired
or the part replaced. If in doubt,
DO NOT
use. Consult your local Clarke
dealer.
SERVICE & REPAIRS
1. If necessary, have your heater repaired by a qualified person using
identical replacement parts. This will ensure that the safety of the
appliance is maintained.
ELECTRICAL CONNECTIONS
DEVIL 370PB & 370SPB 230VOLT HEATER UNITS
The 370 models are provided with a 13 amp BS 1363 plug, fitted with a 13amp
fuse and MUST be connected to a standard, 230 Volt (50Hz) electrical supply,
preferably through a suitably fused isolator switch.
IMPORTANT: The wires in the mains lead should be wired up in accordance
with the following colour code:
Green & Yellow - Earth
Blue - Neutral
Brown - Live
As the colours of the flexible cable of this appliance may not correspond with
the coloured markings identifying terminals in your plug, proceed as follows:
WARNING: THIS APPLIANCE MUST BE EARTHED