background image

4

Parts & Service: 020 8988 7400 / E-mail: [email protected] or [email protected]

sharp edges or moving parts. Damaged or tangled cables increase the risk 
of electric shock.

3. Keep the mains cable well away from any machinery and ensure an 

adequate electrical supply is close at hand so that the operation is not 
restricted by the length of the cable.

4. ALWAYS disconnect from the mains supply before moving the heater, or 

performing any cleaning or maintenance tasks.

5. Inspect the mains cable regularly for signs of damage. DO NOT use if it is 

damaged, and ALWAYS keep it away from the source of heat.

6. Check the heater for damage before use. DO NOT use if the halogen 

tubes are damaged or broken. Any damage should be properly repaired 
or the part replaced. If in doubt, 

DO NOT

 use. Consult your local Clarke 

dealer.

SERVICE & REPAIRS

1. If necessary, have your heater repaired by a qualified person using 

identical replacement parts. This will ensure that the safety of the 
appliance is maintained.

ELECTRICAL CONNECTIONS

DEVIL 370PB & 370SPB 230VOLT HEATER UNITS

The 370 models are provided with a 13 amp BS 1363 plug, fitted with a 13amp 
fuse and MUST be connected to a standard, 230 Volt (50Hz) electrical supply, 
preferably through a suitably fused isolator switch.

IMPORTANT: The wires in the mains lead should be wired up in accordance 
with the following colour code:

                                         Green & Yellow           -           Earth

                                         Blue                        -         Neutral

                                         Brown              -        Live

As the colours of the flexible cable of this appliance may not correspond with 
the coloured markings identifying terminals in your plug, proceed as follows:

WARNING: THIS APPLIANCE MUST BE EARTHED

Summary of Contents for 6926001

Page 1: ...OPERATING MAINTENANCE INSTRUCTIONS ORIGINAL INSTRUCTIONS GC0717 ISSUE 1 DEVIL HALOGEN HEATERS MODEL NO 370PB 370SPB 371PB 371SPB PART NO 6926006 6926001 6926011 6926016 ...

Page 2: ...eceipt which will be required as proof of purchase This guarantee is invalid if the product is found to have been abused or tampered with in any way or not used for the purpose for which it was intended Faulty goods should be returned to their place of purchase no product can be returned to us without prior permission This guarantee does not effect your statutory rights ENVIRONMENTAL RECYCLING POL...

Page 3: ...8 Do not allow the halogen tubes to become covered with dust which could become a fire hazard If used in a dusty workplace the heater should be cleaned as described under Cleaning and Maintenance 9 Do not touch the halogen tubes for at least 15 minutes after switching off 10 Do not leave the heater unattended 11 If children are present always use with a fireguard 12 Store the heater out of the rea...

Page 4: ...r broken Any damage should be properly repaired or the part replaced If in doubt DO NOT use Consult your local Clarke dealer SERVICE REPAIRS 1 If necessary have your heater repaired by a qualified person using identical replacement parts This will ensure that the safety of the appliance is maintained ELECTRICAL CONNECTIONS DEVIL 370PB 370SPB 230VOLT HEATER UNITS The 370 models are provided with a ...

Page 5: ...d by marking or colour code 4 Replacement fuse covers can be obtained from your local Clarke dealer FUSE RATING The fuse in the plug must be replaced with one of the same rating and this replacement must be ASTA approved to BS1362 We strongly recommend that this machine is connected to the mains supply via a Residual Current Device RCD DEVIL 371PB 371SPB 110VOLT HEATER UNITS The 371 models MUST be...

Page 6: ...andle to the heater body using four bolts and plastic blocks supplied 3 Unscrew the front guard and fit the halogen tubes see page 7 DEVIL 370SPB 371SPB 1 Bolt the three parts of the frame together at positions 1 2 2 Attach the frame to the heater body as shown using the locking knobs and the plastic packing pieces at positions 3 4 NOTE The larger packing piece should fit nearer the heater 3 Unscr...

Page 7: ...5 minutes before performing any cleaning or maintenance tasks PERIODICALLY If there is a build up of dirt wipe thoroughly with a damp cloth Take care that no moisture enters the heater Take care NOT to touch the halogen tubes with your fingers Check the mains cable for damage Heat will cause the cable to stiffen and crack If this is found have the cable replaced Check cable routing and ensure it i...

Page 8: ... using the screws removed earlier The heater is now ready for use FAULT FINDING SYMPTOM PROBLEM SOLUTION Heater does not operate although plugged in and switched on Plug is loose bad connection Remove the plug check the connection of the plug and socket Fuse blown Replace if necessary and investigate the cause If fuse blow repeatedly consult your Clarke dealer No power at socket outlet Insert plug...

Page 9: ... No Description 1 Caster standard 2 Caster with Brake 3 Ceramic End Cap 4 Quartz Halogen Tube 5 ON OFF Switch 6 Power Cable 7 Wire Guard 8 Frame SP only 9 Plastic Handle SP only 10 Securing Knob SP only 11 Plastic Saddle SP only 12 Support Bar P only 13 Securing Bolt P only 14 Tilt Safety Switch 15 Rear Handle P only ...

Page 10: ... Number Devil 370PB Devil 370SPB Devil 371PB Devil 371SPB Model Number 6926001 6926006 6926011 6926006 Weight 16 6 kg 16 kg 13 8 kg 14 4 kg Dimensions L x W x H 490 x 563 x 887 mm 490 x 563 x 887 mm 610 x 626 x 788 mm 610 x 626 x 788 mm Wattage 3 kW 3 kW 3 kW 3 kW Amperage 13 A 13 A 27 5 A 27 5 A Supply Voltage 230V 50 hz 230V 50 hz 110V 50hZ 110V 50hZ Fuse Rating 13 A 32 A n a n a Insulation Clas...

Page 11: ...11 Parts Service 020 8988 7400 E mail Parts clarkeinternational com or Service clarkeinternational com DECLARATION OF CONFORMITY ...