AIR COMPRESSOR SAFETY INSTRUCTIONS

1.

ONLY USE WITHIN THE RECOMMENDED OPERATING TEMPERATURE RANGE: 

This compressor should only be used in an ambient temperature of 
b5

O

C and +40

O

C (never at or below freezing temperatures).

2.

NEVER USE AN AIR COMPRESSOR WHICH APPEARS DEFECTIVE OR IS 
OPERATING ABNORMALLY: 

If the compressor operates unusually or makes 

strange noises, switch off immediately and purge the air reservoir. Arrange 
repairs with your nearest dealer.

3.

BREATHING QUALITY AIR: 

This compressor should not be used to supply 

breathing quality air.

4.

SAFETY VALVE: 

Never remove or attempt to adjust the safety valve. The 

maximum pressure is factory set. Keep the safety valve free from paint and 
other accumulations.

5.

AVOID UNINTENTIONAL STARTING: 

Do not move the compressor when it is 

connected to the mains power supply.

6.

BEFORE EACH USE CHECK THE COMPRESSOR AND HOSE FOR DAMAGED 
PARTS: 

Never use the compressor if it has been damaged in any way. Have 

the compressor repaired by a qualified service engineer. Do not use the 
compressor if the On/Off switch does not operate correctly.

7.

KEEP THE MOTOR AIR VENTS CLEAR: 

Keep the motor vents clear and free 

from dust. Wipe regularly to maintain an adequate supply of clean air. 
Avoid using in dusty conditions.

8.

OPERATE THE COMPRESSOR AT THE CORRECT VOLTAGE:

 Make sure that the 

mains supply voltage is the same as the voltage shown on the label.

9.

ALWAYS

 adjust the pressure regulator to the recommended setting for the 

particular spray gun or air tool being used.

10. When using the compressor for painting:

DO NOT 

work in enclosed areas or near naked flames.

Ensure that the area in which you are working has good ventilation.

Protect your nose and mouth with a suitable face mask.

ALWAYS

 check the safety data sheets for substances being sprayed & 

ensure manufacturer’s instructions are followed.

11.

DO NOT USE THIS COMPRESSOR TO INFLATE SMALL, LOW-PRESSURE OBJECTS:

 

Items such as children's toys or footballs can explode if over-inflated.

12.

NEVER STOP THE COMPRESSOR BY REMOVING THE PLUG OR SWITCHING OFF 
AT THE MAINS SUPPLY: 

Always use the On/Off switch on the compressor.

Summary of Contents for 2320875

Page 1: ...OPERATION MAINTENANCE INSTRUCTIONS ORIGINAL INSTRUCTIONS GC1220 rev 10 SILENT AIR COMPRESSOR MODEL NO SHHHAIR 50 24 PART NO 2320875...

Page 2: ...nteed against faulty manufacture for a period of 12 months from the date of purchase Please keep your receipt as proof of purchase This guarantee is invalid if the product is found to have been abused...

Page 3: ...elf against electric shock Never operate the compressor in wet or damp locations 4 NEVER over reach Keep your proper footing and balance at all times to enable better control of the compressor in unex...

Page 4: ...ressure of 10 bar or more should be used Never attempt to repair damaged hoses 8 NEVER abuse the compressor by standing on it AIRLINE HOSES 1 ALWAYS ensure that equipment or power tools used in conjun...

Page 5: ...he compressor repaired by a qualified service engineer Do not use the compressor if the On Off switch does not operate correctly 7 KEEP THE MOTOR AIR VENTS CLEAR Keep the motor vents clear and free fr...

Page 6: ...e colours of the wires in the power cable of this product do not correspond with the markings on the terminals of your plug proceed as follows The Blue wire must be connected to the terminal marked N...

Page 7: ...n on the data label on the side of the compressor The ON OFF switch is in the OFF position Remove any transit caps from the air inlets and replace them with the air inlet filters supplied ADDING OIL T...

Page 8: ...air outlet tap the motor will start automatically once the cut in pressure is reached 2 Allow the compressor to run for 10 15 seconds with the air outlet tap A open This will distribute the lubricati...

Page 9: ...et open the air outlet tap NOTE If the machine pumps continuously without cutting out then the compressor is too small for the application tool being used and damage may result Consult your Clarke dea...

Page 10: ...e the compressor to the sink and place the free end of the small hose in the sink 4 Slowly open the vent valve 5 When the reservoir has been drained re tighten the vent valve and remove the hose DRAIN...

Page 11: ...possible that you are trying to use more air than the compressor is capable of delivering Renew oil filler air Filter plug Air leaking from the pressure switch valve when the compressor is not runnin...

Page 12: ...ons 4 Reassemble the head ensuring the sealing ring is in perfect condition and is located correctly Daily Monthly Yearly Check the oil level X Drain the water collected in the air outlet filter See D...

Page 13: ...y cloth and reassemble the valve taking care to place the internal rubber disc 2 as shown 4 Fasten the valve to the connection and join the flexible hose If the leakage persists the whole valve must b...

Page 14: ...ns that this product must not be disposed of with general household waste It must be disposed of according to the laws governing Waste Electrical and Electronic Equipment WEEE at a recognised disposal...

Page 15: ...15 PARTS DIAGRAM...

Page 16: ...16 PARTS DIAGRAM...

Page 17: ...M F 1 8 CH13 C0126 Rubber Grommet T21 C0354 Draincock M 1 4 90 C0220 Kit Terminal Box T21 230V C0379 Tank Foot C3077 Intake Valve C038244 Tank C3079 Valve Plate Set from s n 18E C038624 Handle C04817...

Page 18: ...18 WIRING DIAGRAM FLOW CHART...

Page 19: ...19 DECLARATION OF CONFORMITY...

Page 20: ......

Reviews: