13
Parts & Service: 020 8988 7400 / E-mail: [email protected] or [email protected]
Compressor
unit runs on
and off load
more
frequently
than usual.
Large amount of
condensation in air receiver.
Drain off condensation
Regularly (Every day
before use).
Leaks in system
Locate leaks (by means of
soapy water) and repair.
Compressor
unit runs ‘on
load’ when
no air is being
used.
Leaks in system
Locate leaks (by means of
soapy water) and repair.
Compressor’s
oil
consumption
rising.
Too much oil in compressor.
Check oil level 2 or
3 minutes after stopping.
Leaks around crank case
Contact Clarke Service
Department
Working temperature of
compressor too high because
of insufficient cooling.
Increase ventilation to air
compressor.
Cylinder worn.
Contact Clarke Service
Department
Intake air filter blocked
Clean or replace
Oil in the air
delivered.
Sump over full
Reduce oil to correct level.
Cylinder worn
Contact Clarke Service
Department
Intake air filter blocked
Clean / Change air filter.
Oil level rises
although no
oil has been
put in.
Condensation in oil pump.
Compressor over
dimensioned.
Condensation
at outlet
points.
Piping installation incorrect.
Consult your local dealer
Compressor taking in air
which is too warm.
Obtain better fresh-air
supply to compressor.
SYMPTOM
PROBABLE CAUSE
REMEDY