![Clarion Ungo MS850 Installation Manual Download Page 17](http://html.mh-extra.com/html/clarion/ungo-ms850/ungo-ms850_installation-manual_2612693017.webp)
MS850 Installation Manual - Page 15
System Initialization and Default Reset
Following this procedure will set all System Programming Parameters to factory default
settings.
1. Turn on ignition.
2. After 4 seconds, press and hold Buttons 1 and 2 together for 5 seconds.
The siren will emit one long chirp, indicating that the reset signal was received.
3. Turn ignition off.
• All System Programming parameters are now set to factory default settings.
• The Arming Mode is set to Remote Arming only.
• The Valet Mode is off.
Arming Mode Selection (Passive or Active Arming)
Using the Remote Transmitter, you may select Passive Arming with chirp confirmation, Passive
Arming without chirp confirmation, or Active Arming (Remote only).
To set the Arming Mode:
1. Turn the ignition on.
2. Within 4 seconds, press Transmitter Buttons 1 and 2 together.
First push:
one chirp
=
Passive Arming with chirp
Second push:
two chirps
=
Active Arming
Third push:
three chirps
=
Passive without chirp
3. Turn off the ignition key to save your selection.
Entering System Programming
1. Turn the ignition on.
2. Within 4 seconds, press Transmintter Button 2.
• The siren will emit one short chirp, indicating that you have entered Programming
Step 1.
• The Status LED will show the current setting of Step 1 (soild of flashing).
3. You can now make changes to the Programmable System Parameters.
Press Button 1 to change the setting.
Press Button 2 to move to the next step.
4. When you are finished, turn the ignition off to save your changes. You can turn the
ignition off at any time during Programming. When the ignition is turned off, the changes
that you have made will be saved.
Programming
installation_850.qxd 9/10/99 6:26 PM Page 15