-12-
13.1 User Parameter Descriptions
1.
Arming Mode:
Selects whether or not the system will automatically Arm when
ignition is turned off.
2.
Auto Rearming:
Selects whether or not the security system will rearm if no
activity is detected after Remote Disarming. (If Passive Door Locking feature
was selected during installation, the system will also relock the doors.)
Automatic Rearming only takes place if the system was Armed (actively or
passively) for at least 10 seconds and then remotely disarmed.
3.
Arming Chirps:
Selects whether or not the security system will chirp when arm
and disarmed.
4.
Ignition Controlled Door Locking:
Selects whether or not the doors will lock
when the ignition is turned On. Ignition Controlled Door Locks will automatically
lock the doors 10 seconds after the ignition is turned On. To prevent the keys
from being locked inside the vehicle; the security system will not lock the doors
if any of the doors is open when the ignition is turned On.
5.
Ignition Controlled Door Unlocking:
Selects whether or not the security
system the doors will unlock when the ignition is turned Off. Ignition Controlled
Door Unlocking can be configured to unlock all the doors or driver's door only.
6.
Override Code Programming:
Selects the number of times the Valet button
must be depressed to override the system. The Override Code can be any
number between 1 and 15. (Default setting is 1)
7.
Remote Start in Valet Mode:
Selects whether or not the remote start can be
activated when the security system is in Valet mode.
8.
Automatic Starting:
Selects the timing interval for the ustomatic remote start
function. When the Automatic Starting feature is enabled by the user, the
vehicle will start and run every 2 hours or every hour depending on the
programming option selected for this step.
9.
Engine Run Time:
Selects the length of time the engine will remain running
during remote start operation.
13.2 Entering User Programming
1. Turn the ignition ON.
2. Within 5 seconds, press the Valet/Override button 2 times and hold for 2
seconds.
The siren will chirp, indicating that User Programming has been entered.
3. Press the Valet/Override button the number of times equal to the Parameter to
be changed.
The siren will chirp each time the Valet/Override button is pressed.
MS2107 install.qxd 8/25/2003 12:50 PM Page 12
Summary of Contents for UNGO MS2105
Page 18: ... 18 18 Dome Light Supervision Relay Diagrams Negative Door Pinswitch Positive Door Pinswitch ...
Page 19: ... 19 19 Trunk Hatch Release Diagrams Negative Trunk Release Wire Positive Trunk Release Wire ...
Page 21: ...Positive Door Lock System 21 22 Door Lock Diagrams Negative Door Lock System ...
Page 22: ... 22 Reverse Polarity Door Lock System ...
Page 23: ... 23 Actuator Diagram ...
Page 24: ... 24 Vacuum Pump System ...
Page 26: ... 26 Positive Door Lock System with Driver s Door Priority ...
Page 27: ... 27 Reverse Polarity Door Lock System with Driver s Door Priority ...