• The shock sensor detects an impact to the vehicle.
• The hood or trunk is opened.
• A connected optional sensor is disturbed.
When triggered, the siren will sound, and the parking lights will flash and the horn will honk (if connected). If the system
is triggered by the doors, hood, or trunk, the system will sound alarm for 40 seconds. If triggered by a sensor, the system
will sound alarm for 20 seconds.
If the same input triggers the system 3 times during a single arming cycle, the system will bypass that input keeping the
other zones protected until the next time the system is armed.
If the shock sensor detects a light impact to the car or a connected optional sensor triggers the system’s Warn Away input,
the siren will sound 5 chirps to warn away the potential intruder.
Remote Sensor Bypass
In case of extreme weather conditions such as high winds, the sensors can be temporarily bypassed from the Remote
Transmitter while the system is armed to prevent the system from false alarming.
To Bypass the sensors:
1. After arming the system, press Button 1 again on the Remote Transmitter within 5 seconds.
• The siren will chirp 5 times, indicating the sensors have been bypassed.
2. The sensors will remain bypassed until the next time the system is armed.
Remote Disarming
To Disarm the System:
Press Button 2.
• The siren/horn will chirp twice.*
• The doors will unlock.
• The parking lights will flash twice.**
• The LED will turn off.
* The siren chirps and light flashes during disarming will alert you if the system had been triggered while armed.
2 chirps / 2 flashes =
normal disarming
3 chirps / 3 flashes =
Tamper Alert - system was triggered
** If the Passenger Unlock Feature is installed, pressing Button 2 will unlock only the driver’s door. Pressing the unlock
Button 2 again unlocks all doors.
Tamper Alert
On Disarming, if the system responds with three chirps, indicating the system was triggered, the LED will flash for 60 seconds
to indicate the zone that triggered the system.
LED Flashes (60 seconds):
1 flash
=
door
2 flashes =
shock sensor
3 flashes =
trunk
4 flashes =
optional sensor
example: flash-flash-pause-flash-flash-pause = shock sensor
Note: Turning on the ignition will cancel Tamper Alert zone indications
.