22
GB
USER INSTRUCTIONS
!
WARNING! Follow the general warnings and the safety norms listed at the
beginning of the text and keep to all the instructions given under all circumstances.
-
Avoid positioning any objects and/or appliances that could be damaged by water
leaks beneath the water heater.
- Should you not use any water for an extended period of time, you should:
"
disconnect the appliance from the electrical supply by switching the external
switch to “OFF”;
"
turn off the plumbing circuit taps.
-
Hot water at above 50
°
C flowing out of the taps at the point of use could cause
serious scalds or even death from burns. Children, the disabled and the elderly are
more exposed to the risk of burns.
-
It is strictly forbidden for the user to perform any routine or extraordinary maintenance.
This appliance may generate hydrogen gas, if left unused for more than 2 weeks.
This type of gas is highly flammable. To reduce the damage that might be caused by
such a situation, the following is recommended:
"
keep the hot water tap turned on for a few minutes before using any electric
household appliance;
"
do not smoke in the vicinity of the point of use;
"
do not light naked flames or gas hob flames near the point of use.
However, water must be drawn from a tap connected to the appliance at least every
3 months to avoid any hydrogen gas build up.
See warning nos. 1 - 2 - 3
See warning no. 4 – Contact a competent person for the replacement of the
power supply cable.
See warning nos. 5 - 6 - 8
See warning no. 21 - To clean the outer parts of the appliance, use a damp
cloth soaked in soapy water.
See warning nos. 22 - 23
To turn the appliance on, press button 1, indicator light A will light up.
Select the desired temperature using button 2, choosing between MIN (~40
°
C), E
(~60
°
C) and MAX (~85
°
C), and the corresponding indictor light C will light up to indicate
!
!
!
!
Advice for user
Operation and adjusting the operating temperature
to enable the diagnosis, which will indicate the type of fault by means of the energy
content LEDS. Each LED indicates a different fault, the LED indicating the fault stays
permanently lit. To quit the diagnosis feature, press the FAST key again for 5 seconds.
N.B.: the Timer/Rate contact open does not lead to the green LED blinking; yet
when the diagnosis is interrogated, it shows with LED 3 the status of the
timer/rate contact as well.
Description of faults:
1. NTC 2 broken (open or short-circuited)
2. NTC 1 broken (open or short-circuited)
3. status of the Timer/Rate contact
!