Purging

To prevent damage to the appliance, the instantaneous water heater must be purged for air before using it 
for the first time. Each time it is emptied (e.g. after work on the plumbing system, if there is a risk of frost or 
following repair work), the appliance must be purged for air before it is used again.

1  Disconnect appliance from the mains by disactivating the fuses.
2  Next, open and close the hot water tap valve several times until no more air emerges from the pipe and 

all air has been eliminated from the water heater (approx. 1 minute).

3  Only then should you reconnect the power supply to the unit.

Maintenance and cleaning

•  Clean the heater and the taps only by wiping with a damp cloth. Do not use abrasive cleaners or solvents.
•  Clean the jet regulator or the hand-shower regularly and replace as necessary.
•  Dirt and scale deposited in the pipes and heater will affect the function of the heater. Typical indications 

of this are a reduced rate of flow or noisy flow. In such cases, have the heater inspected by a technician 
and, if necessary, have the filter in the cold-water inlet cleaned.

Recycling

This symbol on the products and/or accompanying documents means that used electri-
cal and electronic products should not be mixed with general household waste. For 
proper treatment, recovery and recycling, please take these products to designated 
collection points where they will be accepted on a free of charge basis. Alternatively, in 
some countries you may be able to return your products to your local retailer upon the 
purchase of an equivalent new product. Disposing of this product correctly will help to 

save valuable resources and prevent any potential negative effects on human health and the environment 
which could otherwise arise from inappropriate waste handling. Please contact your local authority for fur-
ther details of your nearest designated collection point. Penalties may be applicable for incorrect disposal of 
this waste, in accordance with national legislation. If you are a business user and you wish to discard electri-
cal and electronic equipment, please contact your dealer or supplier for further information. This symbol is 
only valid in the European Union.

Summary of Contents for MDH3

Page 1: ...L PL RUS P CZ S N FIN SK wirtschaftlich warmes Wasser Klein Durchlauferhitzer MH3 7 und MDH3 7 Gebrauchs und Montageanleitung Small instant water heaters MH3 7 and MDH3 7 Operating and installation instructions ...

Page 2: ...Sp ein Ele Ne Elektro Anschlussdose ca 660 ...

Page 3: ...zen liegt dem Gerät bei Elektroanschluss mit Netzleitung ggf kürzen Kabeleingang Waschbeckenoberkante ca 850 Eckventil ca 550 Achse Befestigung ca 520 132 Kabeleingang ca 570 Elektro Anschlussdose ca 660 75 ca 297 187 70 140 17 Maßangaben in mm G 3 8 Eckventil Abgang G 3 8 1 2 ...

Page 4: ...3 Temperaturerhöhung t 1 t 2 in K 4 4 kW 5 7 kW 6 5 kW 3 5 kW Warmwasserleistung l min 40 30 20 10 1 2 1 4 1 7 2 0 2 5 3 0 3 5 4 0 a b 4 5 ...

Page 5: ...7 6 ...

Page 6: ...7 MH 3 7 MDH 3 7 8 g Differenz druckschalter h Heizelement i Sicherheits temperatur begrenzer h Heizelement g Differenz druckschalter ...

Page 7: ...3 MH3 7 MDH3 7 Inhaltsverzeichnis Table of contents Index D GB F NL PL RUS CZ SK S N FIN P ...

Page 8: ... heating wire 9 safety thermal cut out MDH only 10 flow adjustment screw 11 set of small spareparts for spare requirements not included in delivery 1 2 3 9 10 11 4 5 6 7 8 2 Layout of appliance and spareparts Read these operating instructions carefully before installing and using the heater When ordering please always specify the appliance model and serial number ...

Page 9: ... water heater shall supply a single outlet and shall only be used for heating drinking water with a specific water resistance of 800 Ω cm at 15 C Types MH 3 7 may be used only with special safety taps open outlet Use for any other purpose is not permitted When the hot water tap is open the heater switches on automatically and heats the water as it passes through the appliance The hot water temperat...

Page 10: ...cases have the heater inspected by a technician and if necessary have the filter in the cold water inlet cleaned Recycling This symbol on the products and or accompanying documents means that used electri cal and electronic products should not be mixed with general household waste For proper treatment recovery and recycling please take these products to designated collection points where they will ...

Page 11: ...n order to obtain an optimum water jet at low flow rates always screw the enclosed jet regulator onto the tap outlet This insert fits commercially available sleeves with an M22 or M24 thread The following must be observed The heater is installed as shown in the immediate vicinity of the outlet in a frost free room We guarantee trouble free operation only if CLAGE fittings and accessories are used Not...

Page 12: ...n order to avoid water leakage Electrical connection Fill the appliance completely with water by repeatedly opening and closing the tap before connecting to electrical power The heating element may be damaged if this is not done The installation must comply with current IEC regulations or national local regulations or any particular regulations specified by the local electricity supply company The ...

Page 13: ...230 400 2 400 2 V nom power rating 230 400V 3 5 3 5 4 4 4 4 5 7 5 7 6 5 6 5 kW nominal current 15 2 15 2 19 1 19 1 24 8 24 8 16 2 16 2 A req min cross section 1 5 1 5 2 5 2 5 2 5 2 5 2 5 2 5 mm2 hot water output at t 25 K 2 0 2 0 2 5 2 5 3 3 3 3 3 7 3 7 l min switching off 1 2 1 2 1 4 1 4 1 7 1 7 2 0 2 0 l min weight filled with water approx 1 2 1 3 1 2 1 3 1 2 1 3 1 2 1 3 kg dimensions HxWxD 13 2 ...

Page 14: ...chnician and reset the safety thermal cut out circuit breaker appliance does not switch and the water remains cold water connections mixed up check installation water pressure is not sufficient adjust the water flow see fig 7 open the shut off valve dirt in the pipes remove dirt from the inlet and outlet pipes hot water temperature varies water pressure varies stabilise the water flow pressure avoid u...

Page 15: ...20 1401 12 05 GP BA 60 CLAGE GmbH Pirolweg 1 5 21337 Lüneburg Fon 49 0 4131 89 01 0 Fax 49 0 4131 83 200 E Mail info clage de Internet www clage de CLAGE GmbH Zentralkundendienst Fon 49 0 4131 89 01 40 Fax 49 0 4131 89 01 41 E Mail service clage de ...