6. Description of applicance

The Zip instantaneous water heaters are compact electronically controlled water heaters. It is intended to provide economical heating of 
water for a wash basin when installed together with a sanitary water fitting. When the hot-water tap is opened, the heater switches itself 
on automatically when the minimum water flow rate is exceeded and heats the water as it passes through the appliance.

There are 3 available temperature settings, 35ºC, 38ºC and 45ºC (Max).  

For best performance, always fit the special flow controller included with the appliance. This controller is inserted into the outler at the 
end of the tap and fits into any standard sleeve size M 22/24.

The maximum possible outlet temperature is determined by the temperature of the incoming water, the rate of flow and the heating 
power of the appliance.

This appliance delivers water not exceeding 50ºC in accordance with AS3498.  

7. Installation

The following regulations must be observed:

•  Installation must comply with all statutory regulations, AS/NZS 3000, AS/NZS 3500, as well as those of the local electricity and water 

supply companies.

•  The specifications on the rating plate. The rating plate is located under the appliance‘s cover. See Section 10 on removing the cover. 

• Technical specifications.

•  These instructions must be read and fully understood before commencing the installation. If in doubt, or in need of further guidance 

please ring Zip on 1800 638 633.

•  Zip Instantaneous Hot Water heaters must be installed by a competent person familiar with electric instantaneous water heaters.

•  Zip Instantaneous Hot Water heaters must be installed according to the specifi cation on the rating plate and the technical specifi ca-

tions.

•  The appliance must be permanently connected to the electrical supply through an isolation switch as per AS/NZS 3000. 

•  To protect the appliance, a circuit breaker must be fi tted with a rating suitable for the nominal current of the appliance.

•  The cross sectional area of the connection cable must be in accordance with the power rating of the appliance and the specifi c 

requirements of AS/NZS 3000.

•  Take care to protect the wiring from damage during installation and ensure that the wiring is not directly accessible after installation.

•  Check that the power supply is switched off prior to electrical connection.

•  This appliance must be earthed.

Summary of Contents for MCX 27300

Page 1: ...Electronically controlled instantaneous water heater MCX 27300 27400 and 27600 models Installation instructions These appliances deliver water not exceeding 50 C in accordance with AS3498...

Page 2: ...er 5 MCX water connector set with two water connectors and seals mounted and greased fastening safety earthing terminal and filter Pos Part No Description 6 MCX complete fixing set wall bracket with s...

Page 3: ...ent which could other wise arise from inappropriate waste handling Please contact your local authority for further details of your nearest designated collection point Penalties may be applicable for i...

Page 4: ...in case of maintenance the appliance must be vented correctly in accordance with the instructions in this manual Do not remove the front cover under any circumstances before switching off the mains el...

Page 5: ...in 2 5 l min 3 3 l min Maximum temperature increase at rated power and a flow rate of 1 2 0 l min 25 K 31 K 41 K 2 5 l min 20 K 25 K 33 K 3 0 l min 17 K 21 K 27 K 3 5 l min 14 K 18 K 23 K 4 0 l min 12...

Page 6: ...gle valve G1 2 Flow controller MCX3 4 CSP3 MCX6 CSP6 Top edge of wash basin approx 850 Dimensions in mm Electrical connection with mains power cable shorten if necessary Axis wall bracket approx 520 C...

Page 7: ...allation closed outlet with tap for pressurised appliances Dimensions in mm Angle valve approx 550 Top edge of wash basin approx 850 Axis wall bracket approx 520 Cable entry approx 553 MCX3 4 CSP3 MCX...

Page 8: ...AS NZS 3500 as well as those of the local electricity and water supply companies The specifications on the rating plate The rating plate is located under the appliance s cover See Section 10 on remov...

Page 9: ...intenance work a shut off valve should be installed in the supply line The appliance must be accessible for maintenance work The hot water pipes must be thermally insulated See Section 4 for the speci...

Page 10: ...hanical pressure on the appliance by applying a spanner on the flats of the inlet and outlet connections when tightening the pipe connectors Fig 3 2 Once the water connections have been made check for...

Page 11: ...ith current Australian regulations and any Local Authority requirements IMPORTANT The appliance must be installed according to the specification on the rating plate and the technical specifications En...

Page 12: ...der the appliance s cover 9 Flow rate adjustment Removing the cover The rating plate and the adjusting screw for the flow rate is located under the cover 1 Push the cover on the corrugated side toward...

Page 13: ...w rate Turning the adjusting screw counter clockwise increases the flow rate thus reducing the possible outlet temperature 10 Removing the appliance from the wall bracket To remove the appliance from...

Page 14: ...ufficient Increase the water flow to the appliance Slow water flow rate at outlet Flow controller not fitted Fit the correct flow controller see Section 6 or contact Zip Service Water pressure not suf...

Page 15: ...15 Instructions for installer 9120 15004 MCX 801053 March 2013 v1 01 13 Notes...

Page 16: ...cked Bag 80 Bankstown 1885 Australia Website www zipheaters com Facsimile 02 9796 3858 Telephone 02 9796 3100 Free Call 1 800 638 633 As Zip policy is one of continuous product improvement changes to...

Reviews: