MCX 3..7 SMARTRONIC
®
18
10. Elektroanschluss
10. Electrical connection
1
3
2
Circuit diagram
1. Electronic regulator
2. Heating element
3. Safety thermal cut-out
Schaltplan
1. Elektronische Regelung
2. Heizelement
3. Sicherheits temperatur begrenzer
9
(220 V~) MCX 6-220
(240 V~) MCX 3..6-240
(400 V 2~) MCX 7
To prevent damage to the appliance,
the instantaneous water heater must be
purged of air before using it for the first
time.
Each time it is emptied (e.g. after work on
the plumbing system, if there is a risk of frost
or following repair work), the appliance must
be purged of air before it can be used again.
1. Disconnect the appliance from the electri-
cal supply.
2. Open and close the hot water tap until no
more air emerges from the pipe and all
air has been eliminated from the water
heater.
3. Only then you should reconnect the power
supply to the unit.
Um eine Beschädigung des Heizelementes
zu vermeiden, muss das Gerät vor der
erst en Inbetriebnahme entlüftet werden.
Nach jeder Entleerung (z.B. nach Arbeiten in
der Wasser installation, wegen Frostgefahr
oder nach Reparaturen am Gerät) muss das
Gerät vor der Wieder inbetriebnahme erneut
entlüftet werden.
1. Stromzufuhr durch Sicherungen abschal-
ten.
2. Danach das zugehörige Warmwasser zapf-
ventil mehrfach öffnen und schließen, bis
keine Luft mehr aus der Leitung austritt
und der Durchlauf erhitzer luftfrei ist.
3. Erst dann Stromzufuhr zum Durch-
lauferhitzer wieder einschalten.
11. Entlüften
11. Purging