Temperature setting
The temperature selection key allows you to quickly select one of five preset tem
peratures, that are typical for hot water applications:
“Hand wash” 35 °C, “Shower” 38 °C, “Bath tub” 42 °C, “Kitchen” 48 °C and
“Cleaning” 55 °C.
Every key press sets the temperature to the next level:
35 °C
38 °C
42 °C
48 °C
55 °C
Pressing the key once again, starts the cycle all over.
The currently selected temperature is indicated by one of five coloured LEDs.
Five coloured LEDs
Temperature selection key
2. How to use
This instantaneous water heater features an automatic air bubble protection to pre
vent it from inadvertently running dry. Nevertheless, the appliance must be vented
before using it for the first time. Each time the appliance is emptied (e.g. after work on
the plumbing system, if there is a risk of frost or following repair work), the appliance
must be revented before it is used again.
1. Disconnect the instantaneous water heater from the mains (e.g. via deactivating the
fuses).
2. Unscrew the jet regulator on the outlet fitting and open the cold water tap valve to
rinse out the water pipe and avoid contaminating the appliance or the jet regulator.
3. Open and close the hot water tap until no more air emerges from the pipe and all
air has been eliminated from the water heater.
4. Only then should you reconnect the power supply again (e.g. via activating the
fuses) to the instantaneous water heater and screw the jet regulator back in.
5. The appliance activates the heater after approx. 10 seconds of continuous water
flow.
Venting after maintenance work
• Plastic surfaces and fittings should only be wiped with a damp cloth. Do not use
abrasive or chlorinebased cleaning agents or solvents.
• For a good water supply, the outlet fittings (special tap aerators and shower heads)
should be unscrewed and cleaned at regular intervals. Every three years, the electri
cal and plumbing components should be inspected by an authorised professional in
order to ensure proper functioning and operational safety at all times.