3.3.3 REMOVAL
INSTRUCTIONS
IMPORTANT !
a)
Isolate the control valve using main line isolation valves.
b) Bleed pressure from the valve before removing the
e-FlowMeter
c) Disconnect power to all electronic devices on valve,
including e-FlowMeter
a)
Hand loosen the knurled lock from straight threads (Fig.1)
b)
Remove the e-FlowMeter sensor / head assembly by pulling
straight outward (Fig.2), taking extra care to protect the
sensor tip.
1
2
Fig.1
Fig.2